ENERGY STAR PD #3998910 · Range Hood · Qualified 2025-02-21
Verified Specification Summary

The Broan MTR3304SS (RANGE HOOD) moves 160 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 3.8 CFM/W efficacy, sizing bathrooms up to 160 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan MTR3304SS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
160 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
3.8 CFM/W (#951/1,145)
Static Retention
0.1" test only
Motor Draw
42.1 W (15.4 kWh/yr)
Duct & Tier
3.25 x 10 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan MTR3304SS vs. 1,145-Model ENERGY STAR Benchmarks show?

Broan MTR3304SS (EPA filing PD #3998910) omits a published 0.1-inch sone acoustic rating in its current Range Hood certification record.

Free-discharge delivery reaches 160 CFM (#84 of 1,145 certified models) via a 3.25 x 10 in. rectangular exhaust collar without published 0.25 in. w.g. test points. Use a tight rectangular-to-round galvanized transition off the 3.25 x 10 in. rectangular housing before entering attic bays.

Broan maintains 207 active ENERGY STAR blowers; MTR3304SS (series: RANGE HOOD) (PD #3998910) gained qualification on 2025-02-21. Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 42.1 watts, about 15.4 kWh/yr (~$2.46/yr at $0.16/kWh) for 1 hr/day shower timers or 368.8 kWh/yr (~$59.01/yr) continuously. Closest competing matches include Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM) and Broan ALT4306SS (160.0 CFM).

How does duct geometry alter Broan MTR3304SS static pressure?

Smooth 3.25 x 10 in. rectangular galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Broan MTR3304SS?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan MTR3304SS alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series MTR3304SS / RANGE HOOD PD ID 3998910 (Qualified 2025-02-21)
Duct Connection 3.25 x 10 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (160 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Broan MTR3304SS ventilate safely?

Sizing outputs below convert Broan MTR3304SS tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Broan MTR3304SS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 160 sq ft1 CFM/sq ft @ 160 CFM
Tall Bath (9-ft Ceiling)Up to 142 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 110 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)15.4 kWh/yr (~$2.46/yr)42.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2368.8 kWh/yr (~$59.01/yr)42.1 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Broan MTR3304SS closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
Best UCB3I30BLSB 160 / N/A CFM Unpublished 3.2 CFM/W 3.25 in. diameter

Will Broan MTR3304SS clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Broan MTR3304SS satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Where should contractors skip Broan MTR3304SS on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan MTR3304SS carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 110 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 160 sq ft with 8-ft ceilings (142 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 3.25 x 10 in. rectangular

What key rules and numbers govern Broan MTR3304SS?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan MTR3304SS.

What duct and room conditions disqualify Broan MTR3304SS?

Rule out Broan MTR3304SS when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Broan MTR3304SS capacity?

Because static drag at 0.25 in. w.g. lowers Broan MTR3304SS from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 3.25 x 10 in. rectangular rigid ducting straight to a dedicated exterior damper.

How loud is Broan MTR3304SS compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Broan MTR3304SS produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Broan MTR3304SS consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan MTR3304SS draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan MTR3304SS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan MTR3304SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan MTR3304SS?

Broan MTR3304SS features a 3.25 x 10 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan MTR3304SS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan MTR3304SS's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Broan MTR3304SS score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan MTR3304SS delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)