The Broan-Nutone LP510RSL (LP) moves 100 CFM at 0.1 in. w.g. (97 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 9.1 CFM/W efficacy, sizing bathrooms up to 97 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone LP510RSL Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 97 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 9.1 CFM/W (#292/1,145)
- Static Retention
- 97.0% @ 0.25"
- Motor Draw
- 11.0 W (4.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan-Nutone LP510RSL vs. 1,145-Model ENERGY STAR Benchmarks show?
Broan-Nutone LP510RSL (EPA filing PD #2405423) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 97 CFM out of 100 CFM (97.0% retention, 9.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places LP510RSL (series: LP) (PD #2405423) among 48 Broan-Nutone entries qualified through 2022-12-09. Lighting kit: Yes. At 9.1 CFM/W (#292 of 1,145, top 25.9% of 1,145 rated models, more efficient than 74.1% of rated models, 4.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 11.0 watts, about 4.0 kWh/yr (~$0.64/yr at $0.16/kWh) for 1 hr/day shower timers or 96.4 kWh/yr (~$15.42/yr) continuously. Closest competing matches include Delta GBR100LED-DECOR (100.0 CFM) and Delta 100HS (100.0 CFM).
How does duct geometry alter Broan-Nutone LP510RSL static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Broan-Nutone LP510RSL?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Broan-Nutone LP510RSL alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | LP510RSL / LP | PD ID 2405423 (Qualified 2022-12-09) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (97 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Broan-Nutone LP510RSL ventilate safely?
Sizing outputs below convert Broan-Nutone LP510RSL tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 97 sq ft | 1 CFM/sq ft @ 97 CFM |
| Tall Bath (9-ft Ceiling) | Up to 86 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 47 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.0 kWh/yr (~$0.64/yr) | 11.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 96.4 kWh/yr (~$15.42/yr) | 11.0 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Broan-Nutone LP510RSL closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta GBR100LED-DECOR | 100 / 75 CFM | 1.5 sones | 8.4 CFM/W | 4 in. diameter |
| Delta 100HS | 100 / 84.1 CFM | 1.4 sones | 8.1 CFM/W | 4 in. diameter |
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Delta ITG100RLED | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
Will Broan-Nutone LP510RSL clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Broan-Nutone LP510RSL satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does Broan-Nutone LP510RSL fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone LP510RSL.
Limitations & Who Should Skip
- Steam or walk-in tub room > 47 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 97 sq ft with 8-ft ceilings (86 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Broan-Nutone LP510RSL?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Broan-Nutone LP510RSL.
How much airflow does Broan-Nutone LP510RSL retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone LP510RSL produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Will Broan-Nutone LP510RSL disturb adjacent bedrooms during night use?
Acoustic measurement places Broan-Nutone LP510RSL at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Broan-Nutone LP510RSL continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone LP510RSL draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan-Nutone LP510RSL pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone LP510RSL's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone LP510RSL?
Broan-Nutone LP510RSL features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone LP510RSL's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone LP510RSL's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan-Nutone LP510RSL code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone LP510RSL clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan-Nutone LP510RSL?
Do not force Broan-Nutone LP510RSL into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)