Skip to main content
Grant Estimator

Dayton 3DPE7 Exhaust Fan Specifications

ENERGY STAR PD #2366107 · In-line (single-port) · Qualified 2020-08-10
Verified Specification Summary

Certified by EPA ENERGY STAR, Dayton 3DPE7 delivers 94 CFM free-air (85 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 5.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 85 sq ft (8-ft height) or 75 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Dayton 3DPE7 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
94 / 85 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.1 CFM/W (#507/1,145)
Static Retention
90.4% @ 0.25"
Motor Draw
18.4 W (6.7 kWh/yr)
Duct & Tier
6 x 8 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Dayton 3DPE7 vs. 1,145-Model ENERGY STAR Benchmarks show?

Dayton 3DPE7 (EPA filing PD #2366107) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 85 CFM out of 94 CFM (90.4% retention, 2.7 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.

Dayton maintains 12 active ENERGY STAR blowers; 3DPE7 (series: 3DPE7) (PD #2366107) gained qualification on 2020-08-10. Lighting kit: No. At 5.1 CFM/W (#507 of 1,145, top 44.8% of 1,145 rated models, more efficient than 55.2% of rated models, 0.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.4 watts, about 6.7 kWh/yr (~$1.07/yr at $0.16/kWh) for 1 hr/day shower timers or 161.2 kWh/yr (~$25.79/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-V80A (90.0 CFM) and Akicon AK1390N2-B (90.0 CFM).

Why does rigid 6 x 8 in. rectangular ducting protect Dayton 3DPE7 airflow?

Connecting Dayton 3DPE7 through rigid 6 x 8 in. rectangular steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Dayton 3DPE7 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Dayton 3DPE7 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Dayton (12 models) ENERGY STAR Certified Partner
Model Number & Series 3DPE7 / 3DPE7 PD ID 2366107 (Qualified 2020-08-10)
Duct Connection 6 x 8 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (85 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Dayton 3DPE7?

Calculated coverage metrics translate Dayton 3DPE7 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Dayton 3DPE7
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 85 sq ft1 CFM/sq ft @ 85 CFM
Tall Bath (9-ft Ceiling)Up to 75 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 35 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.7 kWh/yr (~$1.07/yr)18.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2161.2 kWh/yr (~$25.79/yr)18.4 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Dayton 3DPE7?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-V80A 90 / 79.2 CFM 1.5 sones 4.3 CFM/W 4 in. diameter
Akicon AK1390N2-B 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-S 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-W 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N3-W/B/S 90 / 71.8 CFM 1.5 sones 4.2 CFM/W 4 in. diameter

Does Dayton 3DPE7 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Dayton 3DPE7 percentage capacity without sending data.

Who should not install Dayton 3DPE7 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Dayton 3DPE7 for residential use.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 35 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Ideal fit: Moisture load fits 85 CFM net static output
  • Primary match: Collar pairs with 6 x 8 in. rectangular duct straight outdoors

Which homeowner questions come up most for Dayton 3DPE7?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Dayton 3DPE7.

How does Dayton 3DPE7 sound output compare to noisy contractor-grade fans?

Rated at an unpublished 0.1-in sone rating, Dayton 3DPE7 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Dayton 3DPE7?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Dayton 3DPE7 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Dayton 3DPE7's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Dayton 3DPE7?

Dayton 3DPE7 features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Dayton 3DPE7's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Dayton 3DPE7's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Dayton 3DPE7 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Dayton 3DPE7 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Dayton 3DPE7 undersized or poorly matched for a bath renovation?

Skip Dayton 3DPE7 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check Dayton 3DPE7 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Dayton 3DPE7 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 6 x 8 in. rectangular duct runs vital.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories