Skip to main content
Grant Estimator

Greenheck CSP-A110 Exhaust Fan Specifications

ENERGY STAR PD #2364772 · In-line (single-port) · Qualified 2020-08-10
Verified Specification Summary

Tested under HVI protocols, the Greenheck CSP-A110 exhaust unit achieves 94 CFM at 0.1 in. w.g. (85 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 5.1 CFM/W efficacy, covering standard baths up to 85 sq ft on a 6 x 8 in. rectangular collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck CSP-A110 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
94 / 85 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.1 CFM/W (#507/1,145)
Static Retention
90.4% @ 0.25"
Motor Draw
18.4 W (6.7 kWh/yr)
Duct & Tier
6 x 8 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck CSP-A110 vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck CSP-A110 (EPA filing PD #2364772) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 85 CFM out of 94 CFM (90.4% retention, 2.7 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 6 x 8 in. rectangular housing before entering attic bays.

Brand catalog footprint: Greenheck registers 31 certified models, with SKU CSP-A110 (series: CSP) (PD #2364772) certified since 2020-08-10. Lighting kit: No. At 5.1 CFM/W (#507 of 1,145, top 44.8% of 1,145 rated models, more efficient than 55.2% of rated models, 0.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 18.4 watts, about 6.7 kWh/yr (~$1.07/yr at $0.16/kWh) for 1 hr/day shower timers or 161.2 kWh/yr (~$25.79/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-V80A (90.0 CFM) and Akicon AK1390N2-B (90.0 CFM).

What attic duct routing preserves Greenheck CSP-A110 CFM output?

Short straight 6 x 8 in. rectangular duct paths retain up to ~82% of open-air capacity on Greenheck CSP-A110, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Greenheck CSP-A110 measure up on airflow and noise ratings?

Each row below breaks down Greenheck CSP-A110 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series CSP-A110 / CSP PD ID 2364772 (Qualified 2020-08-10)
Duct Connection 6 x 8 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (85 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Greenheck CSP-A110 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Greenheck CSP-A110
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 85 sq ft1 CFM/sq ft @ 85 CFM
Tall Bath (9-ft Ceiling)Up to 75 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 35 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.7 kWh/yr (~$1.07/yr)18.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2161.2 kWh/yr (~$25.79/yr)18.4 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Greenheck CSP-A110?

Compare Greenheck CSP-A110 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-V80A 90 / 79.2 CFM 1.5 sones 4.3 CFM/W 4 in. diameter
Akicon AK1390N2-B 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-S 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-W 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N3-W/B/S 90 / 71.8 CFM 1.5 sones 4.2 CFM/W 4 in. diameter

Can you size Greenheck CSP-A110 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Greenheck CSP-A110 verified capacity.

When does Greenheck CSP-A110 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Greenheck CSP-A110.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 85 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 85 sq ft
  • Target scenario: Paired with rigid galvanized 6 x 8 in. rectangular transition

How do federal and code standards apply to Greenheck CSP-A110?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Greenheck CSP-A110.

How much airflow does Greenheck CSP-A110 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Greenheck CSP-A110 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 6 x 8 in. rectangular metal duct transitions.

Will Greenheck CSP-A110 disturb adjacent bedrooms during night use?

Acoustic measurement places Greenheck CSP-A110 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Greenheck CSP-A110 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Greenheck CSP-A110 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Greenheck CSP-A110 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck CSP-A110's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck CSP-A110?

Greenheck CSP-A110 features a 6 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck CSP-A110's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck CSP-A110's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Greenheck CSP-A110 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Greenheck CSP-A110 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Greenheck CSP-A110?

Do not force Greenheck CSP-A110 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories