Skip to main content
Grant Estimator

KOHLER K-34455-NA Exhaust Fan Specifications

ENERGY STAR PD #4528865 · Bathroom/Utility Room · Qualified 2026-01-28
Verified Specification Summary

Rated for 150 CFM open-air (125.1 CFM at 0.25 in. w.g.), KOHLER K-34455-NA omits a published 0.1-inch sone rating and delivers 4.5 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 125 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER K-34455-NA Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
150 / 125.1 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.5 CFM/W (#632/1,145)
Static Retention
83.4% @ 0.25"
Motor Draw
33.3 W (12.2 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does KOHLER K-34455-NA vs. 1,145-Model ENERGY STAR Benchmarks show?

KOHLER K-34455-NA (EPA filing PD #4528865) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Expect noticeable duct drag: airflow moves from 150 CFM open-air to 125.1 CFM at 0.25 in. w.g. (83.4% retention, 4.3 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: KOHLER registers 32 certified models, with SKU K-34455-NA (series: 34455) (PD #4528865) certified since 2026-01-28. Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).

How do flex elbows choke KOHLER K-34455-NA at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps KOHLER K-34455-NA moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does KOHLER K-34455-NA meet residential exhaust fan code specs?

Inspect KOHLER K-34455-NA mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share KOHLER (32 models) ENERGY STAR Certified Partner
Model Number & Series K-34455-NA / 34455 PD ID 4528865 (Qualified 2026-01-28)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (125.1 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match KOHLER K-34455-NA airflow output?

Annual electricity figures and room square-footage ceilings below reflect KOHLER K-34455-NA tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for KOHLER K-34455-NA
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 125 sq ft1 CFM/sq ft @ 125.1 CFM
Tall Bath (9-ft Ceiling)Up to 111 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 75 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)12.2 kWh/yr (~$1.95/yr)33.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2291.7 kWh/yr (~$46.67/yr)33.3 W x 8,760 hrs / 1,000

Which competing models share KOHLER K-34455-NA airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan QT150LE 150 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Tech Drive TD-BF-24L-5CCT(BL) 150 / 138.2 CFM 1.5 sones 4.5 CFM/W 6 in. diameter
Broan ALT4306SS 160 / N/A CFM 1.5 sones 3.2 CFM/W 7 in. diameter
Loren Cook Company GC-242 142 / 112 CFM 1.7 sones 5.3 CFM/W 4.5 x 6 in. rectangular
Broan QT130LE 130 / 126.1 CFM 1.5 sones 4.5 CFM/W 6 in. diameter

How much airflow margin does KOHLER K-34455-NA give your bath?

Run a quick local room-volume check for KOHLER K-34455-NA by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip KOHLER K-34455-NA on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for KOHLER K-34455-NA carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 75 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 125 sq ft with 8-ft ceilings (111 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about KOHLER K-34455-NA?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to KOHLER K-34455-NA.

What duct and room conditions disqualify KOHLER K-34455-NA?

Rule out KOHLER K-34455-NA when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke KOHLER K-34455-NA capacity?

Because static drag at 0.25 in. w.g. lowers KOHLER K-34455-NA from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is KOHLER K-34455-NA compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, KOHLER K-34455-NA produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does KOHLER K-34455-NA consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, KOHLER K-34455-NA draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can KOHLER K-34455-NA pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER K-34455-NA's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing KOHLER K-34455-NA?

KOHLER K-34455-NA features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change KOHLER K-34455-NA's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER K-34455-NA's safe coverage footprint from 50 sq ft to 44 sq ft.

How does KOHLER K-34455-NA score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), KOHLER K-34455-NA delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories