The KOHLER K-34456 (34456) moves 150 CFM at 0.1 in. w.g. (126 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating, and delivers 4.4 CFM/W efficacy, sizing bathrooms up to 126 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside KOHLER K-34456 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 150 / 126 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 84.0% @ 0.25"
- Motor Draw
- 34.1 W (12.4 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does KOHLER K-34456 vs. 1,145-Model ENERGY STAR Benchmarks show?
KOHLER K-34456 (EPA filing PD #4528847) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Expect noticeable duct drag: airflow moves from 150 CFM open-air to 126 CFM at 0.25 in. w.g. (84.0% retention, 3.7 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
KOHLER maintains 32 active ENERGY STAR blowers; K-34456 (series: 34456) (PD #4528847) gained qualification on 2026-01-28. Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 34.1 watts, about 12.4 kWh/yr (~$1.98/yr at $0.16/kWh) for 1 hr/day shower timers or 298.7 kWh/yr (~$47.79/yr) continuously. Closest competing matches include Broan QT150LE (150.0 CFM) and Tech Drive TD-BF-24L-5CCT(BL) (150.0 CFM).
How does duct geometry alter KOHLER K-34456 static pressure?
Smooth 6 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to KOHLER K-34456?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for KOHLER K-34456 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | KOHLER (32 models) | ENERGY STAR Certified Partner |
| Model Number & Series | K-34456 / 34456 | PD ID 4528847 (Qualified 2026-01-28) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (126 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can KOHLER K-34456 ventilate safely?
Sizing outputs below convert KOHLER K-34456 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 126 sq ft | 1 CFM/sq ft @ 126 CFM |
| Tall Bath (9-ft Ceiling) | Up to 112 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 76 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 12.4 kWh/yr (~$1.98/yr) | 34.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 298.7 kWh/yr (~$47.79/yr) | 34.1 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match KOHLER K-34456 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan QT150LE | 150 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-24L-5CCT(BL) | 150 / 138.2 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
| Broan ALT4306SS | 160 / N/A CFM | 1.5 sones | 3.2 CFM/W | 7 in. diameter |
| Loren Cook Company GC-242 | 142 / 112 CFM | 1.7 sones | 5.3 CFM/W | 4.5 x 6 in. rectangular |
| Broan QT130LE | 130 / 126.1 CFM | 1.5 sones | 4.5 CFM/W | 6 in. diameter |
Will KOHLER K-34456 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether KOHLER K-34456 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Does KOHLER K-34456 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying KOHLER K-34456 for your remodel.
Limitations & Who Should Skip
- Steam or walk-in tub room > 76 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 126 sq ft with 8-ft ceilings (112 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 6 in. diameter
What key rules and numbers govern KOHLER K-34456?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting KOHLER K-34456.
What acoustic sone tier does KOHLER K-34456 occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., KOHLER K-34456 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does KOHLER K-34456 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, KOHLER K-34456 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can KOHLER K-34456 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from KOHLER K-34456's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing KOHLER K-34456?
KOHLER K-34456 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change KOHLER K-34456's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing KOHLER K-34456's safe coverage footprint from 50 sq ft to 44 sq ft.
Does KOHLER K-34456 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), KOHLER K-34456 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install KOHLER K-34456 in a bathroom remodel?
Avoid specifying KOHLER K-34456 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut KOHLER K-34456 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, KOHLER K-34456 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)