Rated for 100 CFM open-air (102.5 CFM at 0.25 in. w.g.), Panasonic FV-0510VSCAB1 omits a published 0.1-inch sone rating and delivers 8.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 102 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0510VSCAB1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 100 / 102.5 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 8.1 CFM/W (#338/1,145)
- Static Retention
- 102.5% @ 0.25"
- Motor Draw
- 12.3 W (4.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic FV-0510VSCAB1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic FV-0510VSCAB1 (EPA filing PD #4429315) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 102.5 CFM out of 100 CFM (102.5% retention, 14.8 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4429315 verifies FV-0510VSCAB1 (series: Whisper Value) under Panasonic (92 listed models, qualified 2025-04-25). Lighting kit: No. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.3 watts, about 4.5 kWh/yr (~$0.72/yr at $0.16/kWh) for 1 hr/day shower timers or 107.7 kWh/yr (~$17.23/yr) continuously. Closest competing matches include Delta ITG100ELED (100.0 CFM) and Delta ITG100RLED (100.0 CFM).
How do flex elbows choke Panasonic FV-0510VSCAB1 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Panasonic FV-0510VSCAB1 moving full rated CFM.
Does Panasonic FV-0510VSCAB1 meet residential exhaust fan code specs?
Inspect Panasonic FV-0510VSCAB1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-0510VSCAB1 / Whisper Value | PD ID 4429315 (Qualified 2025-04-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (102.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Panasonic FV-0510VSCAB1 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Panasonic FV-0510VSCAB1 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 102 sq ft | 1 CFM/sq ft @ 102.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 91 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 52 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.5 kWh/yr (~$0.72/yr) | 12.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 107.7 kWh/yr (~$17.23/yr) | 12.3 W x 8,760 hrs / 1,000 |
Which competing models share Panasonic FV-0510VSCAB1 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta ITG100ELED | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Delta ITG100RLED | 100 / 89.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02 | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-BN | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
| Utilitech 7115-02-CH | 100 / 84.9 CFM | 1.5 sones | 7.8 CFM/W | 4 in. diameter |
How much airflow margin does Panasonic FV-0510VSCAB1 give your bath?
Run a quick local room-volume check for Panasonic FV-0510VSCAB1 by entering square footage and ceiling height to spot under-vented steam risks early.
When does Panasonic FV-0510VSCAB1 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Panasonic FV-0510VSCAB1.
Limitations & Who Should Skip
- Steam or walk-in tub room > 52 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 102 sq ft with 8-ft ceilings (91 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Panasonic FV-0510VSCAB1?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Panasonic FV-0510VSCAB1.
Will Panasonic FV-0510VSCAB1 disturb adjacent bedrooms during night use?
Acoustic measurement places Panasonic FV-0510VSCAB1 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Panasonic FV-0510VSCAB1 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Panasonic FV-0510VSCAB1 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Panasonic FV-0510VSCAB1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0510VSCAB1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV-0510VSCAB1?
Panasonic FV-0510VSCAB1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV-0510VSCAB1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0510VSCAB1's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Panasonic FV-0510VSCAB1 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0510VSCAB1 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Panasonic FV-0510VSCAB1?
Do not force Panasonic FV-0510VSCAB1 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Panasonic FV-0510VSCAB1 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Panasonic FV-0510VSCAB1 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)