Skip to main content
Grant Estimator

Panasonic FV-0709VBL1 Exhaust Fan Specifications

ENERGY STAR PD #4586486 · Bathroom/Utility Room · Qualified 2026-01-07
Verified Specification Summary

Certified by EPA ENERGY STAR, Panasonic FV-0709VBL1 delivers 90 CFM free-air (77.5 CFM at 0.25 in. w.g.) and omits a published 0.1-inch sone rating and delivers 4.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 77 sq ft (8-ft height) or 68 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-0709VBL1 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
90 / 77.5 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.1 CFM/W (#821/1,145)
Static Retention
86.1% @ 0.25"
Motor Draw
22.0 W (8.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-0709VBL1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-0709VBL1 (EPA filing PD #4586486) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 77.5 CFM out of 90 CFM (86.1% retention, 1.6 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Panasonic registers 92 certified models, with SKU FV-0709VBL1 (series: EcoVent) (PD #4586486) certified since 2026-01-07. Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.0 watts, about 8.0 kWh/yr (~$1.28/yr at $0.16/kWh) for 1 hr/day shower timers or 192.7 kWh/yr (~$30.83/yr) continuously. Closest competing matches include Akicon AK1390N1-W/B/S (90.0 CFM) and Tech Drive TD-BF-11 (90.0 CFM).

Why does rigid 4 in. diameter ducting protect Panasonic FV-0709VBL1 airflow?

Connecting Panasonic FV-0709VBL1 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Panasonic FV-0709VBL1 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Panasonic FV-0709VBL1 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-0709VBL1 / EcoVent PD ID 4586486 (Qualified 2026-01-07)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (77.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Panasonic FV-0709VBL1?

Calculated coverage metrics translate Panasonic FV-0709VBL1 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Panasonic FV-0709VBL1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 77 sq ft1 CFM/sq ft @ 77.5 CFM
Tall Bath (9-ft Ceiling)Up to 68 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 27 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.0 kWh/yr (~$1.28/yr)22.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2192.7 kWh/yr (~$30.83/yr)22.0 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Panasonic FV-0709VBL1?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Akicon AK1390N1-W/B/S 90 / 67.4 CFM 1.5 sones 4.1 CFM/W 4 in. diameter
Tech Drive TD-BF-11 90 / 82 CFM 1.5 sones 4.0 CFM/W 4 in. diameter
Akicon AK1390N2-B 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-S 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-W 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter

Does Panasonic FV-0709VBL1 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Panasonic FV-0709VBL1 percentage capacity without sending data.

Which bath layouts should avoid specifying Panasonic FV-0709VBL1?

Match Panasonic FV-0709VBL1 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 27 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 77.5 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Panasonic FV-0709VBL1?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Panasonic FV-0709VBL1.

Where does Panasonic FV-0709VBL1 sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, Panasonic FV-0709VBL1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Panasonic FV-0709VBL1 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Panasonic FV-0709VBL1 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Panasonic FV-0709VBL1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-0709VBL1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-0709VBL1?

Panasonic FV-0709VBL1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-0709VBL1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-0709VBL1's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Panasonic FV-0709VBL1 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-0709VBL1 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Panasonic FV-0709VBL1 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Panasonic FV-0709VBL1.

What happens to Panasonic FV-0709VBL1 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Panasonic FV-0709VBL1 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories