Homeowners specifying Panasonic FV07VB1 gain 90 CFM at 0.1 in. w.g. (79.2 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.3 CFM/W efficacy, venting bathrooms up to 79 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV07VB1 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 79.2 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 88.0% @ 0.25"
- Motor Draw
- 20.9 W (7.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic FV07VB1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic FV07VB1 (EPA filing PD #2344292) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 79.2 CFM out of 90 CFM (88.0% retention, 0.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Manufacturer coverage places FV07VB1 (series: Eco-Vent) (PD #2344292) among 92 Panasonic entries qualified through 2019-08-09. Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.9 watts, about 7.6 kWh/yr (~$1.22/yr at $0.16/kWh) for 1 hr/day shower timers or 183.1 kWh/yr (~$29.30/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-V80A (90.0 CFM) and Akicon AK1390N2-B (90.0 CFM).
Which exterior damper path suits Panasonic FV07VB1 best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Panasonic FV07VB1 housings.
Where do Panasonic FV07VB1 acoustic and static metrics stand?
Compare Panasonic FV07VB1 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV07VB1 / Eco-Vent | PD ID 2344292 (Qualified 2019-08-09) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (79.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can Panasonic FV07VB1 handle taller ceilings or walk-in tub steam?
Evaluate how Panasonic FV07VB1 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 79 sq ft | 1 CFM/sq ft @ 79.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 29 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.6 kWh/yr (~$1.22/yr) | 20.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 183.1 kWh/yr (~$29.30/yr) | 20.9 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Panasonic FV07VB1?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic Eco Solutions RG-V80A | 90 / 79.2 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| Akicon AK1390N2-B | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N2-S | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N2-W | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N3-W/B/S | 90 / 71.8 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
Is Panasonic FV07VB1 sized right for your shower or tub room?
Check whether Panasonic FV07VB1 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
What plumbing or duct constraints rule out Panasonic FV07VB1?
Compare where Panasonic FV07VB1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 29 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 79.2 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for Panasonic FV07VB1?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Panasonic FV07VB1.
Why might a contractor swap Panasonic FV07VB1 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Panasonic FV07VB1 lacks adequate reserve.
How does Panasonic FV07VB1 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Panasonic FV07VB1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Panasonic FV07VB1 quiet enough for a primary bedroom bathroom?
At an unpublished 0.1-in sone rating, Panasonic FV07VB1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Panasonic FV07VB1 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Panasonic FV07VB1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV07VB1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV07VB1?
Panasonic FV07VB1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV07VB1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV07VB1's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Panasonic FV07VB1 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Panasonic FV07VB1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)