Tested under HVI protocols, the Panasonic FV-07VBA1A+FV-07VBB1 exhaust unit achieves 90 CFM at 0.1 in. w.g. (79.2 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 4.3 CFM/W efficacy, covering standard baths up to 79 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-07VBA1A+FV-07VBB1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 90 / 79.2 CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 88.0% @ 0.25"
- Motor Draw
- 20.9 W (7.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Panasonic FV-07VBA1A+FV-07VBB1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Panasonic FV-07VBA1A+FV-07VBB1 (EPA filing PD #2347889) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 79.2 CFM out of 90 CFM (88.0% retention, 0.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2347889 verifies FV-07VBA1A+FV-07VBB1 (series: EcoVent) under Panasonic (92 listed models, qualified 2019-08-23). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.9 watts, about 7.6 kWh/yr (~$1.22/yr at $0.16/kWh) for 1 hr/day shower timers or 183.1 kWh/yr (~$29.30/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-V80A (90.0 CFM) and Akicon AK1390N2-B (90.0 CFM).
What attic duct routing preserves Panasonic FV-07VBA1A+FV-07VBB1 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic FV-07VBA1A+FV-07VBB1, preventing premature peeling paint and mold growth.
How does Panasonic FV-07VBA1A+FV-07VBB1 measure up on airflow and noise ratings?
Each row below breaks down Panasonic FV-07VBA1A+FV-07VBB1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Panasonic (92 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FV-07VBA1A+FV-07VBB1 / EcoVent | PD ID 2347889 (Qualified 2019-08-23) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (79.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Panasonic FV-07VBA1A+FV-07VBB1 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 79 sq ft | 1 CFM/sq ft @ 79.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 70 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 29 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.6 kWh/yr (~$1.22/yr) | 20.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 183.1 kWh/yr (~$29.30/yr) | 20.9 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Panasonic FV-07VBA1A+FV-07VBB1?
Compare Panasonic FV-07VBA1A+FV-07VBB1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic Eco Solutions RG-V80A | 90 / 79.2 CFM | 1.5 sones | 4.3 CFM/W | 4 in. diameter |
| Akicon AK1390N2-B | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N2-S | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N2-W | 90 / 71.7 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
| Akicon AK1390N3-W/B/S | 90 / 71.8 CFM | 1.5 sones | 4.2 CFM/W | 4 in. diameter |
Can you size Panasonic FV-07VBA1A+FV-07VBB1 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic FV-07VBA1A+FV-07VBB1 verified capacity.
Does Panasonic FV-07VBA1A+FV-07VBB1 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-07VBA1A+FV-07VBB1 for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 79.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around ENERGY STAR sones up to 79 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Panasonic FV-07VBA1A+FV-07VBB1?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic FV-07VBA1A+FV-07VBB1.
Does Panasonic FV-07VBA1A+FV-07VBB1 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-07VBA1A+FV-07VBB1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Panasonic FV-07VBA1A+FV-07VBB1 in a bathroom remodel?
Avoid specifying Panasonic FV-07VBA1A+FV-07VBB1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Panasonic FV-07VBA1A+FV-07VBB1 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-07VBA1A+FV-07VBB1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Panasonic FV-07VBA1A+FV-07VBB1 occupy in EPA filings?
With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-07VBA1A+FV-07VBB1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.
How many kWh per year does Panasonic FV-07VBA1A+FV-07VBB1 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Panasonic FV-07VBA1A+FV-07VBB1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Panasonic FV-07VBA1A+FV-07VBB1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-07VBA1A+FV-07VBB1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Panasonic FV-07VBA1A+FV-07VBB1?
Panasonic FV-07VBA1A+FV-07VBB1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Panasonic FV-07VBA1A+FV-07VBB1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-07VBA1A+FV-07VBB1's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)