Panasonic FV-07VBA1A+FV-07VBB1 Exhaust Fan Specifications

ENERGY STAR PD #2347889 · Bathroom/Utility Room · Qualified 2019-08-23
Verified Specification Summary

Tested under HVI protocols, the Panasonic FV-07VBA1A+FV-07VBB1 exhaust unit achieves 90 CFM at 0.1 in. w.g. (79.2 CFM at 0.25 in. w.g.), omits a published 0.1-inch sone rating and delivers 4.3 CFM/W efficacy, covering standard baths up to 79 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Panasonic FV-07VBA1A+FV-07VBB1 Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
90 / 79.2 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.3 CFM/W (#718/1,145)
Static Retention
88.0% @ 0.25"
Motor Draw
20.9 W (7.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Panasonic FV-07VBA1A+FV-07VBB1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Panasonic FV-07VBA1A+FV-07VBB1 (EPA filing PD #2347889) omits a published 0.1-inch sone acoustic rating in its current Bathroom/Utility Room certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 79.2 CFM out of 90 CFM (88.0% retention, 0.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2347889 verifies FV-07VBA1A+FV-07VBB1 (series: EcoVent) under Panasonic (92 listed models, qualified 2019-08-23). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.9 watts, about 7.6 kWh/yr (~$1.22/yr at $0.16/kWh) for 1 hr/day shower timers or 183.1 kWh/yr (~$29.30/yr) continuously. Closest competing matches include Panasonic Eco Solutions RG-V80A (90.0 CFM) and Akicon AK1390N2-B (90.0 CFM).

What attic duct routing preserves Panasonic FV-07VBA1A+FV-07VBB1 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Panasonic FV-07VBA1A+FV-07VBB1, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Panasonic FV-07VBA1A+FV-07VBB1 measure up on airflow and noise ratings?

Each row below breaks down Panasonic FV-07VBA1A+FV-07VBB1 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Panasonic (92 models) ENERGY STAR Certified Partner
Model Number & Series FV-07VBA1A+FV-07VBB1 / EcoVent PD ID 2347889 (Qualified 2019-08-23)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (79.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Panasonic FV-07VBA1A+FV-07VBB1 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Panasonic FV-07VBA1A+FV-07VBB1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 79 sq ft1 CFM/sq ft @ 79.2 CFM
Tall Bath (9-ft Ceiling)Up to 70 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 29 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.6 kWh/yr (~$1.22/yr)20.9 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2183.1 kWh/yr (~$29.30/yr)20.9 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Panasonic FV-07VBA1A+FV-07VBB1?

Compare Panasonic FV-07VBA1A+FV-07VBB1 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic Eco Solutions RG-V80A 90 / 79.2 CFM 1.5 sones 4.3 CFM/W 4 in. diameter
Akicon AK1390N2-B 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-S 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N2-W 90 / 71.7 CFM 1.5 sones 4.2 CFM/W 4 in. diameter
Akicon AK1390N3-W/B/S 90 / 71.8 CFM 1.5 sones 4.2 CFM/W 4 in. diameter

Can you size Panasonic FV-07VBA1A+FV-07VBB1 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Panasonic FV-07VBA1A+FV-07VBB1 verified capacity.

Does Panasonic FV-07VBA1A+FV-07VBB1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Panasonic FV-07VBA1A+FV-07VBB1 for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 79.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around ENERGY STAR sones up to 79 sq ft
  • Best application: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Panasonic FV-07VBA1A+FV-07VBB1?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Panasonic FV-07VBA1A+FV-07VBB1.

Does Panasonic FV-07VBA1A+FV-07VBB1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Panasonic FV-07VBA1A+FV-07VBB1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Panasonic FV-07VBA1A+FV-07VBB1 in a bathroom remodel?

Avoid specifying Panasonic FV-07VBA1A+FV-07VBB1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Panasonic FV-07VBA1A+FV-07VBB1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Panasonic FV-07VBA1A+FV-07VBB1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Panasonic FV-07VBA1A+FV-07VBB1 occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., Panasonic FV-07VBA1A+FV-07VBB1 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Panasonic FV-07VBA1A+FV-07VBB1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Panasonic FV-07VBA1A+FV-07VBB1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Panasonic FV-07VBA1A+FV-07VBB1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Panasonic FV-07VBA1A+FV-07VBB1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Panasonic FV-07VBA1A+FV-07VBB1?

Panasonic FV-07VBA1A+FV-07VBB1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Panasonic FV-07VBA1A+FV-07VBB1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Panasonic FV-07VBA1A+FV-07VBB1's safe coverage footprint from 50 sq ft to 44 sq ft.