Skip to main content
Grant Estimator

QuFresh FA100X Exhaust Fan Specifications

ENERGY STAR PD #4698114 · In-line (single-port) · Qualified 2026-09-02
Verified Specification Summary

Tested under HVI protocols, the QuFresh FA100X exhaust unit achieves 110 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 8.1 CFM/W efficacy, covering standard baths up to 110 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside QuFresh FA100X Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.1 CFM/W (#338/1,145)
Static Retention
0.1" test only
Motor Draw
13.6 W (5.0 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does QuFresh FA100X vs. 1,145-Model ENERGY STAR Benchmarks show?

QuFresh FA100X (EPA filing PD #4698114) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 110 CFM (#317 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside QuFresh's 6-unit lineup, FA100X (series: FA100X) carries PD #4698114 dating to 2026-09-02. Lighting kit: No. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.6 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 119.1 kWh/yr (~$19.06/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Delta ITG100ELED (100.0 CFM).

What attic duct routing preserves QuFresh FA100X CFM output?

Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on QuFresh FA100X, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does QuFresh FA100X measure up on airflow and noise ratings?

Each row below breaks down QuFresh FA100X certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share QuFresh (6 models) ENERGY STAR Certified Partner
Model Number & Series FA100X / FA100X PD ID 4698114 (Qualified 2026-09-02)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (110 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect QuFresh FA100X CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for QuFresh FA100X
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 110 sq ft1 CFM/sq ft @ 110 CFM
Tall Bath (9-ft Ceiling)Up to 97 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 60 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.0 kWh/yr (~$0.80/yr)13.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2119.1 kWh/yr (~$19.06/yr)13.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against QuFresh FA100X?

Compare QuFresh FA100X side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

Can you size QuFresh FA100X for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against QuFresh FA100X verified capacity.

Which bath layouts should avoid specifying QuFresh FA100X?

Match QuFresh FA100X directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 110 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around ENERGY STAR sones up to 110 sq ft
  • Optimal use: Paired with rigid galvanized 6 in. diameter transition

How do federal and code standards apply to QuFresh FA100X?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for QuFresh FA100X.

What happens to QuFresh FA100X CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, QuFresh FA100X moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.

Where does QuFresh FA100X sit on acoustic comfort for senior homeowners?

Measuring an unpublished 0.1-in sone rating, QuFresh FA100X produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does QuFresh FA100X cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running QuFresh FA100X 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can QuFresh FA100X pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from QuFresh FA100X's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing QuFresh FA100X?

QuFresh FA100X features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change QuFresh FA100X's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing QuFresh FA100X's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can QuFresh FA100X ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), QuFresh FA100X covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does QuFresh FA100X run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with QuFresh FA100X.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories