ENERGY STAR PD #4682900 · In-line (single-port) · Qualified 2026-08-05
Verified Specification Summary

Rated for 110 CFM open-air (unpublished 0.25 in. w.g. output), QuFresh QUF100X omits a published 0.1-inch sone rating and delivers 8.1 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 110 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside QuFresh QUF100X Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
110 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
8.1 CFM/W (#338/1,145)
Static Retention
0.1" test only
Motor Draw
13.6 W (5.0 kWh/yr)
Duct & Tier
6 in. diameter · Most Eff.
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does QuFresh QUF100X vs. 1,145-Model ENERGY STAR Benchmarks show?

QuFresh QUF100X (EPA filing PD #4682900) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 110 CFM (#317 of 1,145 certified models) via a 6 in. diameter exhaust collar without published 0.25 in. w.g. test points. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places QUF100X (series: QUF100X) (PD #4682900) among 6 QuFresh entries qualified through 2026-08-05. Lighting kit: No. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 13.6 watts, about 5.0 kWh/yr (~$0.80/yr at $0.16/kWh) for 1 hr/day shower timers or 119.1 kWh/yr (~$19.06/yr) continuously. Closest competing matches include Utilitech UTLDS110 (110.0 CFM) and Delta ITG100ELED (100.0 CFM).

How do flex elbows choke QuFresh QUF100X at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps QuFresh QUF100X moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does QuFresh QUF100X meet residential exhaust fan code specs?

Inspect QuFresh QUF100X mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share QuFresh (6 models) ENERGY STAR Certified Partner
Model Number & Series QUF100X / QUF100X PD ID 4682900 (Qualified 2026-08-05)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (110 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match QuFresh QUF100X airflow output?

Annual electricity figures and room square-footage ceilings below reflect QuFresh QUF100X tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for QuFresh QUF100X
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 110 sq ft1 CFM/sq ft @ 110 CFM
Tall Bath (9-ft Ceiling)Up to 97 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 60 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.0 kWh/yr (~$0.80/yr)13.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2119.1 kWh/yr (~$19.06/yr)13.6 W x 8,760 hrs / 1,000

Which competing models share QuFresh QUF100X airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Utilitech UTLDS110 110 / 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta ITG100ELED 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Delta ITG100RLED 100 / 89.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter
Utilitech 7115-02-BN 100 / 84.9 CFM 1.5 sones 7.8 CFM/W 4 in. diameter

How much airflow margin does QuFresh QUF100X give your bath?

Run a quick local room-volume check for QuFresh QUF100X by entering square footage and ceiling height to spot under-vented steam risks early.

Does QuFresh QUF100X suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying QuFresh QUF100X for your remodel.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 60 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 110 sq ft with 8-ft ceilings (97 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 6 in. diameter

What should homeowners verify first about QuFresh QUF100X?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to QuFresh QUF100X.

How many kWh per year does QuFresh QUF100X add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, QuFresh QUF100X averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can QuFresh QUF100X pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from QuFresh QUF100X's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing QuFresh QUF100X?

QuFresh QUF100X features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change QuFresh QUF100X's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing QuFresh QUF100X's safe coverage footprint from 50 sq ft to 44 sq ft.

Does QuFresh QUF100X pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), QuFresh QUF100X easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install QuFresh QUF100X in a bathroom remodel?

Avoid specifying QuFresh QUF100X in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut QuFresh QUF100X airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, QuFresh QUF100X achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does QuFresh QUF100X occupy in EPA filings?

With an unpublished 0.1-in sone rating at 0.1 in. w.g., QuFresh QUF100X produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)