Rated for 460 CFM open-air (unpublished 0.25 in. w.g. output), Fantech FG 10 EC omits a published 0.1-inch sone rating and delivers 5.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 460 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 10 EC Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
460 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
5.2 CFM/W (#499/1,145)
Static Retention
0.1" test only
Motor Draw
88.5 W (32.3 kWh/yr)
Duct & Tier
1 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech FG 10 EC vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FG 10 EC (EPA filing PD #2346015) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 460 CFM (#3 of 1,145 certified models) via a 1 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 1 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Fantech FG 10 EC (series: FG 10 EC) under PD #2346015 (52 models registered, 2019-09-06). Lighting kit: No. At 5.2 CFM/W (#499 of 1,145, top 44.2% of 1,145 rated models, more efficient than 55.8% of rated models, 0.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 88.5 watts, about 32.3 kWh/yr (~$5.17/yr at $0.16/kWh) for 1 hr/day shower timers or 775.3 kWh/yr (~$124.05/yr) continuously. Closest competing matches include Delta VDBFRS200 (200.0 CFM) and Delta VDBFRS200HT (200.0 CFM).

How do flex elbows choke Fantech FG 10 EC at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 1 in. diameter metal pipe keeps Fantech FG 10 EC moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Fantech FG 10 EC meet residential exhaust fan code specs?

Inspect Fantech FG 10 EC mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series FG 10 EC / FG 10 EC PD ID 2346015 (Qualified 2019-09-06)
Duct Connection 1 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (460 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Fantech FG 10 EC airflow output?

Annual electricity figures and room square-footage ceilings below reflect Fantech FG 10 EC tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Fantech FG 10 EC
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 460 sq ft1 CFM/sq ft @ 460 CFM
Tall Bath (9-ft Ceiling)Up to 408 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 410 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)32.3 kWh/yr (~$5.17/yr)88.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2775.3 kWh/yr (~$124.05/yr)88.5 W x 8,760 hrs / 1,000

Which competing models share Fantech FG 10 EC airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta VDBFRS200 200 / N/A CFM Unpublished 5.3 CFM/W 6 in. diameter
Delta VDBFRS200HT 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200HT-P 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDB200 200 / N/A CFM Unpublished 6.6 CFM/W 6 in. diameter
Broan FIN-180B 180 / N/A CFM Unpublished 6.8 CFM/W 6 in. diameter

How much airflow margin does Fantech FG 10 EC give your bath?

Run a quick local room-volume check for Fantech FG 10 EC by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Fantech FG 10 EC on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Fantech FG 10 EC carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 410 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 460 sq ft with 8-ft ceilings (408 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 1 in. diameter

What should homeowners verify first about Fantech FG 10 EC?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Fantech FG 10 EC.

Will long attic ducting choke Fantech FG 10 EC capacity?

Because static drag at 0.25 in. w.g. lowers Fantech FG 10 EC from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 1 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Fantech FG 10 EC compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Fantech FG 10 EC produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Fantech FG 10 EC consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Fantech FG 10 EC draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Fantech FG 10 EC pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 10 EC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech FG 10 EC?

Fantech FG 10 EC features a 1 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech FG 10 EC's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 10 EC's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Fantech FG 10 EC score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Fantech FG 10 EC delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Fantech FG 10 EC?

Rule out Fantech FG 10 EC when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories