Tested under HVI protocols, the S&P TD-200S exhaust unit achieves 460 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 4.0 CFM/W efficacy, covering standard baths up to 460 sq ft on a 8 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P TD-200S Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 460 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 4.0 CFM/W (#847/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 115.0 W (42.0 kWh/yr)
- Duct & Tier
- 8 in. diameter · Standard

What does S&P TD-200S vs. 1,145-Model ENERGY STAR Benchmarks show?
S&P TD-200S (EPA filing PD #2394999) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 460 CFM (#3 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms S&P TD-200S (series: TD Silent) under PD #2394999 (29 models registered, 2022-04-22). Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 115.0 watts, about 42.0 kWh/yr (~$6.72/yr at $0.16/kWh) for 1 hr/day shower timers or 1007.4 kWh/yr (~$161.18/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).
What attic duct routing preserves S&P TD-200S CFM output?
Short straight 8 in. diameter duct paths retain up to ~82% of open-air capacity on S&P TD-200S, preventing premature peeling paint and mold growth.
How does S&P TD-200S measure up on airflow and noise ratings?
Each row below breaks down S&P TD-200S certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-200S / TD Silent | PD ID 2394999 (Qualified 2022-04-22) |
| Duct Connection | 8 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (460 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect S&P TD-200S CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 460 sq ft | 1 CFM/sq ft @ 460 CFM |
| Tall Bath (9-ft Ceiling) | Up to 408 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 410 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 42.0 kWh/yr (~$6.72/yr) | 115.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 1007.4 kWh/yr (~$161.18/yr) | 115.0 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against S&P TD-200S?
Compare S&P TD-200S side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta VDBFRS200HT | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDBFRS200HT-P | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDBFRS200 | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| Delta VDB200 | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| Broan FIN-180B | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |
Can you size S&P TD-200S for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against S&P TD-200S verified capacity.
Where should contractors skip S&P TD-200S on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for S&P TD-200S carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 460 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Choose this if: Target comfort around ENERGY STAR sones up to 460 sq ft
- Works well for: Paired with rigid galvanized 8 in. diameter transition
How do federal and code standards apply to S&P TD-200S?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for S&P TD-200S.
How does S&P TD-200S score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), S&P TD-200S delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify S&P TD-200S?
Rule out S&P TD-200S when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Will long attic ducting choke S&P TD-200S capacity?
Because static drag at 0.25 in. w.g. lowers S&P TD-200S from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 8 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is S&P TD-200S compared with a standard 3.0 sone builder fan?
Tested at an unpublished 0.1-in sone rating, S&P TD-200S produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.
How much power does S&P TD-200S consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, S&P TD-200S draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can S&P TD-200S pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P TD-200S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P TD-200S?
S&P TD-200S features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P TD-200S's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P TD-200S's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)