The S&P TD-200 (MixVent TD) moves 430 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating, and delivers 3.9 CFM/W efficacy, sizing bathrooms up to 430 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P TD-200 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 430 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 110.3 W (40.3 kWh/yr)
- Duct & Tier
- 8 in. diameter · Standard

What does S&P TD-200 vs. 1,145-Model ENERGY STAR Benchmarks show?
S&P TD-200 (EPA filing PD #2343144) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 430 CFM (#6 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2343144 verifies TD-200 (series: MixVent TD) under S&P (29 listed models, qualified 2015-09-01). Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 110.3 watts, about 40.3 kWh/yr (~$6.45/yr at $0.16/kWh) for 1 hr/day shower timers or 966.2 kWh/yr (~$154.59/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).
How does duct geometry alter S&P TD-200 static pressure?
Smooth 8 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to S&P TD-200?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for S&P TD-200 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TD-200 / MixVent TD | PD ID 2343144 (Qualified 2015-09-01) |
| Duct Connection | 8 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (430 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How much bathroom area can S&P TD-200 ventilate safely?
Sizing outputs below convert S&P TD-200 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 430 sq ft | 1 CFM/sq ft @ 430 CFM |
| Tall Bath (9-ft Ceiling) | Up to 382 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 380 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 40.3 kWh/yr (~$6.45/yr) | 110.3 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 966.2 kWh/yr (~$154.59/yr) | 110.3 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match S&P TD-200 closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta VDBFRS200HT | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDBFRS200HT-P | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDBFRS200 | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| Delta VDB200 | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| Broan FIN-180B | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |
Will S&P TD-200 clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether S&P TD-200 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
When does S&P TD-200 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering S&P TD-200.
Limitations & Who Should Skip
- Steam or walk-in tub room > 380 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 430 sq ft with 8-ft ceilings (382 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 8 in. diameter
What key rules and numbers govern S&P TD-200?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting S&P TD-200.
How much airflow does S&P TD-200 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, S&P TD-200 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 8 in. diameter metal duct transitions.
Will S&P TD-200 disturb adjacent bedrooms during night use?
Acoustic measurement places S&P TD-200 at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running S&P TD-200 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of S&P TD-200 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can S&P TD-200 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P TD-200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P TD-200?
S&P TD-200 features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P TD-200's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P TD-200's safe coverage footprint from 50 sq ft to 44 sq ft.
Is S&P TD-200 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), S&P TD-200 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than S&P TD-200?
Do not force S&P TD-200 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)