Fantech FGC 8 (40423) Exhaust Fan Specifications

ENERGY STAR PD #4429506 · In-line (single-port) · Qualified 2025-06-06
Verified Specification Summary

Tested under HVI protocols, the Fantech FGC 8 (40423) exhaust unit achieves 390 CFM at 0.1 in. w.g. (unpublished 0.25 in. w.g. output), omits a published 0.1-inch sone rating and delivers 4.0 CFM/W efficacy, covering standard baths up to 390 sq ft on a 8 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FGC 8 (40423) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
390 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.0 CFM/W (#847/1,145)
Static Retention
0.1" test only
Motor Draw
97.5 W (35.6 kWh/yr)
Duct & Tier
8 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech FGC 8 (40423) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FGC 8 (40423) (EPA filing PD #4429506) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 390 CFM (#7 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Fantech FGC 8 (40423) (series: FG 8 Series) under PD #4429506 (52 models registered, 2025-06-06). Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 97.5 watts, about 35.6 kWh/yr (~$5.70/yr at $0.16/kWh) for 1 hr/day shower timers or 854.1 kWh/yr (~$136.66/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

What attic duct routing preserves Fantech FGC 8 (40423) CFM output?

Short straight 8 in. diameter duct paths retain up to ~82% of open-air capacity on Fantech FGC 8 (40423), preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Fantech FGC 8 (40423) measure up on airflow and noise ratings?

Each row below breaks down Fantech FGC 8 (40423) certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series FGC 8 (40423) / FG 8 Series PD ID 4429506 (Qualified 2025-06-06)
Duct Connection 8 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (390 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Fantech FGC 8 (40423) CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Fantech FGC 8 (40423)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 390 sq ft1 CFM/sq ft @ 390 CFM
Tall Bath (9-ft Ceiling)Up to 346 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 340 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)35.6 kWh/yr (~$5.70/yr)97.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2854.1 kWh/yr (~$136.66/yr)97.5 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Fantech FGC 8 (40423)?

Compare Fantech FGC 8 (40423) side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta VDBFRS200HT 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200HT-P 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200 200 / N/A CFM Unpublished 5.3 CFM/W 6 in. diameter
Delta VDB200 200 / N/A CFM Unpublished 6.6 CFM/W 6 in. diameter
Broan FIN-180B 180 / N/A CFM Unpublished 6.8 CFM/W 6 in. diameter

Can you size Fantech FGC 8 (40423) for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Fantech FGC 8 (40423) verified capacity.

When does Fantech FGC 8 (40423) fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Fantech FGC 8 (40423).

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 390 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around ENERGY STAR sones up to 390 sq ft
  • Target scenario: Paired with rigid galvanized 8 in. diameter transition

How do federal and code standards apply to Fantech FGC 8 (40423)?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Fantech FGC 8 (40423).

Does running Fantech FGC 8 (40423) continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Fantech FGC 8 (40423) draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Fantech FGC 8 (40423) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FGC 8 (40423)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech FGC 8 (40423)?

Fantech FGC 8 (40423) features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech FGC 8 (40423)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FGC 8 (40423)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Is Fantech FGC 8 (40423) code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Fantech FGC 8 (40423) clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Fantech FGC 8 (40423)?

Do not force Fantech FGC 8 (40423) into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Fantech FGC 8 (40423) retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Fantech FGC 8 (40423) produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 8 in. diameter metal duct transitions.

Will Fantech FGC 8 (40423) disturb adjacent bedrooms during night use?

Acoustic measurement places Fantech FGC 8 (40423) at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.