In EPA dataset 8dv7-nngq, Fantech FG 8 EC tests at 380 CFM free discharge (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 5.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 380 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 8 EC Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 380 / N/A CFM
- Noise @ 0.1"
- Unpublished
- Efficacy Rank
- 5.5 CFM/W (#471/1,145)
- Static Retention
- 0.1" test only
- Motor Draw
- 69.1 W (25.2 kWh/yr)
- Duct & Tier
- 8 in. diameter · Standard

What does Fantech FG 8 EC vs. 1,145-Model ENERGY STAR Benchmarks show?
Fantech FG 8 EC (EPA filing PD #2346865) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.
Free-discharge delivery reaches 380 CFM (#10 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Fantech registers 52 certified models, with SKU FG 8 EC (series: FG 8 EC) (PD #2346865) certified since 2019-09-20. Lighting kit: No. At 5.5 CFM/W (#471 of 1,145, top 42.8% of 1,145 rated models, more efficient than 57.2% of rated models, 0.8 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 69.1 watts, about 25.2 kWh/yr (~$4.03/yr at $0.16/kWh) for 1 hr/day shower timers or 605.3 kWh/yr (~$96.85/yr) continuously. Closest competing matches include Delta VDBFRS200 (200.0 CFM) and Delta VDBFRS200HT (200.0 CFM).
Why avoid unvented attic termination with Fantech FG 8 EC?
Under ASHRAE 62.2 best practice, Fantech FG 8 EC needs insulated 8 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Fantech FG 8 EC?
Before cutting ceiling drywall or sizing attic transitions for Fantech FG 8 EC, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Fantech (52 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FG 8 EC / FG 8 EC | PD ID 2346865 (Qualified 2019-09-20) |
| Duct Connection | 8 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (380 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | Unpublished | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Fantech FG 8 EC?
Bathroom ventilation sizing below maps Fantech FG 8 EC motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 380 sq ft | 1 CFM/sq ft @ 380 CFM |
| Tall Bath (9-ft Ceiling) | Up to 337 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 330 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 25.2 kWh/yr (~$4.03/yr) | 69.1 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 605.3 kWh/yr (~$96.85/yr) | 69.1 W x 8,760 hrs / 1,000 |
What peer models sit nearest Fantech FG 8 EC in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Fantech FG 8 EC.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Delta VDBFRS200 | 200 / N/A CFM | Unpublished | 5.3 CFM/W | 6 in. diameter |
| Delta VDBFRS200HT | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDBFRS200HT-P | 200 / N/A CFM | Unpublished | 4.9 CFM/W | 6 in. diameter |
| Delta VDB200 | 200 / N/A CFM | Unpublished | 6.6 CFM/W | 6 in. diameter |
| Broan FIN-180B | 180 / N/A CFM | Unpublished | 6.8 CFM/W | 6 in. diameter |
What percentage of room demand does Fantech FG 8 EC cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Fantech FG 8 EC tested delivery.
When does Fantech FG 8 EC fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Fantech FG 8 EC.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 380 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Recommended when: Target comfort around ENERGY STAR sones up to 380 sq ft
- Target scenario: Paired with rigid galvanized 8 in. diameter transition
Where do official rules set limits for Fantech FG 8 EC?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Fantech FG 8 EC.
Will Fantech FG 8 EC disturb adjacent bedrooms during night use?
Acoustic measurement places Fantech FG 8 EC at an unpublished 0.1-in sone rating, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.
Does running Fantech FG 8 EC continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Fantech FG 8 EC draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Fantech FG 8 EC pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 8 EC's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Fantech FG 8 EC?
Fantech FG 8 EC features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Fantech FG 8 EC's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 8 EC's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Fantech FG 8 EC code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Fantech FG 8 EC clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Fantech FG 8 EC?
Do not force Fantech FG 8 EC into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Fantech FG 8 EC retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Fantech FG 8 EC produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 8 in. diameter metal duct transitions.