Skip to main content
Grant Estimator

Greenheck CSP-A390-VG Exhaust Fan Specifications

ENERGY STAR PD #2353546 · In-line (single-port) · Qualified 2019-12-10
Verified Specification Summary

Homeowners specifying Greenheck CSP-A390-VG gain 388 CFM at 0.1 in. w.g. (359 CFM at 0.25 in. w.g.) where it omits a published 0.1-inch sone rating and delivers 4.9 CFM/W efficacy, venting bathrooms up to 359 sq ft cleanly through 8 x 8 in. rectangular rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck CSP-A390-VG Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
388 / 359 CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.9 CFM/W (#519/1,145)
Static Retention
92.5% @ 0.25"
Motor Draw
79.2 W (28.9 kWh/yr)
Duct & Tier
8 x 8 in. rectangular · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck CSP-A390-VG vs. 1,145-Model ENERGY STAR Benchmarks show?

Greenheck CSP-A390-VG (EPA filing PD #2353546) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 359 CFM out of 388 CFM (92.5% retention, 4.8 pts higher retention than the 87.7% median). Use a tight rectangular-to-round galvanized transition off the 8 x 8 in. rectangular housing before entering attic bays.

Greenheck maintains 31 active ENERGY STAR blowers; CSP-A390-VG (series: CSP) (PD #2353546) gained qualification on 2019-12-10. Lighting kit: No. At 4.9 CFM/W (#519 of 1,145, top 46.6% of 1,145 rated models, more efficient than 53.4% of rated models, 0.2 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 79.2 watts, about 28.9 kWh/yr (~$4.62/yr at $0.16/kWh) for 1 hr/day shower timers or 693.8 kWh/yr (~$111.01/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

Which exterior damper path suits Greenheck CSP-A390-VG best?

Exterior roof or wall damper termination paired with insulated 8 x 8 in. rectangular metal pipe prevents condensation buildup around Greenheck CSP-A390-VG housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Greenheck CSP-A390-VG acoustic and static metrics stand?

Compare Greenheck CSP-A390-VG published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series CSP-A390-VG / CSP PD ID 2353546 (Qualified 2019-12-10)
Duct Connection 8 x 8 in. rectangular Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (359 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Greenheck CSP-A390-VG handle taller ceilings or walk-in tub steam?

Evaluate how Greenheck CSP-A390-VG scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Greenheck CSP-A390-VG
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 359 sq ft1 CFM/sq ft @ 359 CFM
Tall Bath (9-ft Ceiling)Up to 319 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 309 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)28.9 kWh/yr (~$4.62/yr)79.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2693.8 kWh/yr (~$111.01/yr)79.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Greenheck CSP-A390-VG?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta VDBFRS200HT 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200HT-P 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200 200 / N/A CFM Unpublished 5.3 CFM/W 6 in. diameter
Delta VDB200 200 / N/A CFM Unpublished 6.6 CFM/W 6 in. diameter
Broan FIN-180B 180 / N/A CFM Unpublished 6.8 CFM/W 6 in. diameter

Is Greenheck CSP-A390-VG sized right for your shower or tub room?

Check whether Greenheck CSP-A390-VG clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

What plumbing or duct constraints rule out Greenheck CSP-A390-VG?

Compare where Greenheck CSP-A390-VG excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 309 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 359 CFM net static output
  • Suited to: Collar pairs with 8 x 8 in. rectangular duct straight outdoors

Which code checks and cost facts matter for Greenheck CSP-A390-VG?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Greenheck CSP-A390-VG.

Why might a contractor swap Greenheck CSP-A390-VG for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Greenheck CSP-A390-VG lacks adequate reserve.

How does Greenheck CSP-A390-VG handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Greenheck CSP-A390-VG yields unlisted 0.25 in. w.g. backpressure figures, so smooth 8 x 8 in. rectangular rigid metal ducting protects real exhaust.

Is Greenheck CSP-A390-VG quiet enough for a primary bedroom bathroom?

At an unpublished 0.1-in sone rating, Greenheck CSP-A390-VG produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Greenheck CSP-A390-VG energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Greenheck CSP-A390-VG pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck CSP-A390-VG's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck CSP-A390-VG?

Greenheck CSP-A390-VG features a 8 x 8 in. rectangular collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck CSP-A390-VG's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck CSP-A390-VG's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Greenheck CSP-A390-VG serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Greenheck CSP-A390-VG supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories