Skip to main content
Grant Estimator

Fantech FG 8 (40408) Exhaust Fan Specifications

ENERGY STAR PD #4016345 · In-line (single-port) · Qualified 2025-04-25
Verified Specification Summary

Certified by EPA ENERGY STAR, Fantech FG 8 (40408) delivers 390 CFM free-air (unpublished 0.25 in. w.g. output) and omits a published 0.1-inch sone rating and delivers 4.0 CFM/W efficacy, clearing residential IRC M1505 sizing up to 390 sq ft (8-ft height) or 346 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Fantech FG 8 (40408) Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
390 / N/A CFM
Noise @ 0.1"
Unpublished
Efficacy Rank
4.0 CFM/W (#847/1,145)
Static Retention
0.1" test only
Motor Draw
97.5 W (35.6 kWh/yr)
Duct & Tier
8 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Fantech FG 8 (40408) vs. 1,145-Model ENERGY STAR Benchmarks show?

Fantech FG 8 (40408) (EPA filing PD #4016345) omits a published 0.1-inch sone acoustic rating in its current In-line (single-port) certification record.

Free-discharge delivery reaches 390 CFM (#7 of 1,145 certified models) via a 8 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 8 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Fantech registers 52 certified models, with SKU FG 8 (40408) (series: FG Series) (PD #4016345) certified since 2025-04-25. Lighting kit: No. At 4.0 CFM/W (#847 of 1,145, below median tier among 1,145 rated models; more efficient than 23.6% of rated models, 0.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 97.5 watts, about 35.6 kWh/yr (~$5.70/yr at $0.16/kWh) for 1 hr/day shower timers or 854.1 kWh/yr (~$136.66/yr) continuously. Closest competing matches include Delta VDBFRS200HT (200.0 CFM) and Delta VDBFRS200HT-P (200.0 CFM).

Why does rigid 8 in. diameter ducting protect Fantech FG 8 (40408) airflow?

Connecting Fantech FG 8 (40408) through rigid 8 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Fantech FG 8 (40408) performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Fantech FG 8 (40408) lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Fantech (52 models) ENERGY STAR Certified Partner
Model Number & Series FG 8 (40408) / FG Series PD ID 4016345 (Qualified 2025-04-25)
Duct Connection 8 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (390 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) Unpublished Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Fantech FG 8 (40408)?

Calculated coverage metrics translate Fantech FG 8 (40408) airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Fantech FG 8 (40408)
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 390 sq ft1 CFM/sq ft @ 390 CFM
Tall Bath (9-ft Ceiling)Up to 346 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 340 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)35.6 kWh/yr (~$5.70/yr)97.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2854.1 kWh/yr (~$136.66/yr)97.5 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Fantech FG 8 (40408)?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Delta VDBFRS200HT 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200HT-P 200 / N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Delta VDBFRS200 200 / N/A CFM Unpublished 5.3 CFM/W 6 in. diameter
Delta VDB200 200 / N/A CFM Unpublished 6.6 CFM/W 6 in. diameter
Broan FIN-180B 180 / N/A CFM Unpublished 6.8 CFM/W 6 in. diameter

Does Fantech FG 8 (40408) match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Fantech FG 8 (40408) percentage capacity without sending data.

Where should contractors skip Fantech FG 8 (40408) on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Fantech FG 8 (40408) carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 340 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 390 CFM net static output
  • Works well for: Collar pairs with 8 in. diameter duct straight outdoors

Which homeowner questions come up most for Fantech FG 8 (40408)?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Fantech FG 8 (40408).

How does Fantech FG 8 (40408) score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Fantech FG 8 (40408) delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Fantech FG 8 (40408)?

Rule out Fantech FG 8 (40408) when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Fantech FG 8 (40408) capacity?

Because static drag at 0.25 in. w.g. lowers Fantech FG 8 (40408) from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 8 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Fantech FG 8 (40408) compared with a standard 3.0 sone builder fan?

Tested at an unpublished 0.1-in sone rating, Fantech FG 8 (40408) produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Fantech FG 8 (40408) consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Fantech FG 8 (40408) draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Fantech FG 8 (40408) pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Fantech FG 8 (40408)'s 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Fantech FG 8 (40408)?

Fantech FG 8 (40408) features a 8 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Fantech FG 8 (40408)'s room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Fantech FG 8 (40408)'s safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories