Skip to main content
Grant Estimator

ENERGY STAR Bathroom Exhaust Fans — Models 691–805

Catalog section (Models 691–805 of 1,145 total certified blowers) from U.S. EPA ENERGY STAR dataset 8dv7-nngq.
Direct Reference Summary

This catalog slice lists 115 ENERGY STAR certified bathroom exhaust fans (Models 691-805 out of 1,145 nationwide) with tested airflow at 0.1 in. and 0.25 in. w.g., acoustic sones (fleet median 1.0 sones), and motor efficacy (median 4.7 CFM/W). Compare verified EPA WaterSense and ENERGY STAR certified assemblies filtered from active public registries for ENERGY STAR Bathroom Exhaust Fans — Models 691–805 before ordering valves or trim.

Models Shown
115
Total Catalog
1,145
Median Efficacy
4.7 CFM/W
Median CFM
110 CFM
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

How have U.S. plumbing and remodeling material costs shifted from 2021 to 2026?

BLS Producer Price Index trajectories climbed steeply from 349.2 in 2021 to 452.8 through late 2026, setting clear baseline separation between labor pay and supply inflation.

BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Bar trend chart for BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026) across 6 periods (2021 to 2026). First: 349.1; latest: 452.8.BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Unit: idx0.0226.4452.82021: 349.1349.120212022: 385.5385.520222023: 395.0395.020232024: 401.4401.420242025: 424.1424.120252026: 452.8452.82026

How does exhaust duct geometry change static pressure?

Smooth 4-in or 6-in rigid steel ducts terminated outdoors preserve ~82% of rated fan CFM at 0.25 in. w.g., while sagging 3-in attic flex ducts choke airflow below code minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which ENERGY STAR Bathroom Exhaust Fans — Models 691–805 records match your engineering filters?

Filter verified government registry entries by threshold category or type a brand, model SKU, or state keyword below to narrow matching records instantaneously.

ENERGY STAR fan Models 691–805 — filter by acoustic tier or search by brand
Fantech FG 8 (40408) 390.0 CFM N/A CFM Unpublished 4.0 CFM/W 8 in. diameter
Fantech FGC 8 (40423) 390.0 CFM N/A CFM Unpublished 4.0 CFM/W 8 in. diameter
Greenheck CSP-A390-VG 388.0 CFM 359.0 CFM Unpublished 4.9 CFM/W 8 x 8 in. rectangular
Fantech FG 8 EC 380.0 CFM N/A CFM Unpublished 5.5 CFM/W 8 in. diameter
Fantech FGC 8 EC 380.0 CFM N/A CFM Unpublished 5.5 CFM/W 8 in. diameter
Ortech OIF8-560 380.0 CFM N/A CFM Unpublished 4.2 CFM/W 8 in. diameter
Fantech FG 6M EC 330.0 CFM N/A CFM Unpublished 4.4 CFM/W 6 in. diameter
Fantech FGC 6M EC 330.0 CFM N/A CFM Unpublished 4.4 CFM/W 6 in. diameter
Broan L300E 310.0 CFM 285.9 CFM Unpublished 4.4 CFM/W 8 in. diameter
Ortech ODDIN-300 300.0 CFM N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
S&P PCD300IL 300.0 CFM N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Ortech ODD-300-3 292.0 CFM 263.2 CFM Unpublished 6.5 CFM/W 6 in. diameter
Fantech FR 150 (411334) 280.0 CFM N/A CFM Unpublished 4.3 CFM/W 6 in. diameter
Broan L250E 270.0 CFM 245.0 CFM Unpublished 4.6 CFM/W 8 in. diameter
Broan L300EL 270.0 CFM N/A CFM Unpublished 3.9 CFM/W 8 in. diameter
S&P TD-150S 270.0 CFM N/A CFM Unpublished 4.5 CFM/W 6 in. diameter
Fantech FG 6 (40406) 260.0 CFM N/A CFM Unpublished 3.9 CFM/W 6 in. diameter
Fantech FGC 6 (40381) 260.0 CFM N/A CFM Unpublished 3.9 CFM/W 6 in. diameter
Fantech PB 270-2 (40572) 260.0 CFM N/A CFM Unpublished 3.9 CFM/W 6 in. diameter
Fantech PB 270L10-2 (44945) 260.0 CFM N/A CFM Unpublished 3.9 CFM/W 6 in. diameter
Fantech PB 270L10V2 (44947) 260.0 CFM N/A CFM Unpublished 3.9 CFM/W 6 in. diameter
Fantech PB 270L7-2 (44944) 260.0 CFM N/A CFM Unpublished 3.9 CFM/W 6 in. diameter
Fantech PB 270L710-2 (44948) 260.0 CFM N/A CFM Unpublished 3.9 CFM/W 6 in. diameter
Fantech PB 270L7V-2 (44946) 260.0 CFM N/A CFM Unpublished 3.9 CFM/W 6 in. diameter
S&P TD-150 260.0 CFM N/A CFM Unpublished 4.3 CFM/W 6 in. diameter
Broan L200E 240.0 CFM 205.9 CFM Unpublished 4.7 CFM/W 8 in. diameter
Broan L250EL 230.0 CFM N/A CFM Unpublished 3.9 CFM/W 8 in. diameter
Dayton 6WZN6 213.0 CFM 204.0 CFM Unpublished 3.9 CFM/W 8 x 8 in. rectangular
Greenheck CSP-A200 213.0 CFM 204.0 CFM Unpublished 3.9 CFM/W 8 x 6 in. rectangular
Broan L150E 210.0 CFM 175.2 CFM Unpublished 5.0 CFM/W 8 in. diameter
Broan L200EL 200.0 CFM N/A CFM Unpublished 4.0 CFM/W 8 in. diameter
Delta SMT150-200 200.0 CFM 203.4 CFM Unpublished 8.7 CFM/W 6 in. diameter
Delta SMT150-200LED 200.0 CFM 204.9 CFM Unpublished 10.3 CFM/W 6 in. diameter
Fantech FreshFlow(579865) 200.0 CFM N/A CFM Unpublished 5.4 CFM/W 6 in. diameter
Zephyr ZSI-E30BS-ES 200.0 CFM N/A CFM Unpublished 3.5 CFM/W 8 in. diameter
Zephyr ZSI-E36BS-ES 200.0 CFM N/A CFM Unpublished 3.5 CFM/W 8 in. diameter
Aprilaire 8145 190.0 CFM N/A CFM Unpublished 4.4 CFM/W 6 in. diameter
Aprilaire 8145NC 190.0 CFM N/A CFM Unpublished 4.4 CFM/W 6 in. diameter
Broan ALT4306SS 190.0 CFM N/A CFM Unpublished 3.7 CFM/W 3.25 x 14 in. rectangular
Broan FIN-180P 180.0 CFM N/A CFM Unpublished 6.4 CFM/W 6 in. diameter
Broan FIN-180P-HW 180.0 CFM N/A CFM Unpublished 6.4 CFM/W 6 in. diameter
Ortech OIF5-190 180.0 CFM N/A CFM Unpublished 4.9 CFM/W 5 in. diameter
Broan L150EL 170.0 CFM N/A CFM Unpublished 4.2 CFM/W 8 in. diameter
S&P RF10-160EC 170.0 CFM N/A CFM Unpublished 5.2 CFM/W 6 in. diameter
S&P RF10-160EC-ES24V 170.0 CFM N/A CFM Unpublished 5.2 CFM/W 6 in. diameter
S&P RF10-160EC-P 170.0 CFM N/A CFM Unpublished 5.2 CFM/W 6 in. diameter
S&P RF10-160EC-P-ES24V 170.0 CFM N/A CFM Unpublished 5.2 CFM/W 6 in. diameter
Best UCB3I30BLSB 160.0 CFM N/A CFM Unpublished 3.2 CFM/W 3.25 in. diameter
Best UCB3I30SBB 160.0 CFM N/A CFM Unpublished 3.2 CFM/W 3.25 in. diameter
Best UCB3I30SBN 160.0 CFM N/A CFM Unpublished 3.2 CFM/W 3.25 in. diameter
Best UCB3I30SBS 160.0 CFM N/A CFM Unpublished 3.2 CFM/W 3.25 in. diameter
Best UCB3I30SBW 160.0 CFM N/A CFM Unpublished 3.2 CFM/W 3.25 in. diameter
Broan ALT3304SS 160.0 CFM N/A CFM Unpublished 3.7 CFM/W 3.25 x 10 in. rectangular
Broan ALT3304WW 160.0 CFM N/A CFM Unpublished 3.8 CFM/W 3.25 x 10 in. rectangular
Broan ALT4306SS 160.0 CFM N/A CFM Unpublished 3.1 CFM/W 3.25 x 10 in. rectangular
Broan GLA3304SS 160.0 CFM N/A CFM Unpublished 3.8 CFM/W 3.25 x 10 in. rectangular
Broan GLA3304WW 160.0 CFM N/A CFM Unpublished 3.8 CFM/W 3.25 x 10 in. rectangular
Broan GLA3364SS 160.0 CFM N/A CFM Unpublished 3.8 CFM/W 3.25 x 10 in. rectangular
Broan MTR3304SS 160.0 CFM N/A CFM Unpublished 3.8 CFM/W 3.25 x 10 in. rectangular
Commercial Electric BF1115 160.0 CFM 129.4 CFM Unpublished 4.4 CFM/W 6 in. diameter
Fantech FG 4XL EC (56015) 160.0 CFM N/A CFM Unpublished 4.8 CFM/W 4 in. diameter
Revent RVSC120140160 160.0 CFM 164.7 CFM Unpublished 10.9 CFM/W 6 in. diameter
S&P TD-125 160.0 CFM N/A CFM Unpublished 4.5 CFM/W 5 in. diameter
Air King E110S 150.0 CFM 111.8 CFM Unpublished 4.5 CFM/W 6 in. diameter
Air King E130S 150.0 CFM 113.5 CFM Unpublished 4.5 CFM/W 6 in. diameter
Air King E130SH 150.0 CFM 113.5 CFM Unpublished 4.5 CFM/W 6 in. diameter
Air King EVD 150.0 CFM 113.5 CFM Unpublished 4.5 CFM/W 6 in. diameter
Air King EVDG 150.0 CFM 113.5 CFM Unpublished 4.5 CFM/W 6 in. diameter
Air King EVDGH 150.0 CFM 113.5 CFM Unpublished 4.5 CFM/W 6 in. diameter
Air King EVDH 150.0 CFM 113.5 CFM Unpublished 4.5 CFM/W 6 in. diameter
Air King EVLD 150.0 CFM 112.4 CFM Unpublished 4.6 CFM/W 6 in. diameter
Air King EVLDGH 150.0 CFM 112.4 CFM Unpublished 4.6 CFM/W 6 in. diameter
Air King EVLDH 150.0 CFM 112.4 CFM Unpublished 4.6 CFM/W 6 in. diameter
Broan ALT1303SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan ALT1303WW 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan ALT2303BLS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan ALT2303SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan BCSEK124BL 150.0 CFM N/A CFM Unpublished 5.5 CFM/W 7 in. diameter
Broan BCSEK124SS 150.0 CFM N/A CFM Unpublished 5.5 CFM/W 7 in. diameter
Broan BCSEK124WW 150.0 CFM N/A CFM Unpublished 5.5 CFM/W 7 in. diameter
Broan BCSEK130BL 150.0 CFM N/A CFM Unpublished 5.5 CFM/W 7 in. diameter
Broan BCSEK130SS 150.0 CFM N/A CFM Unpublished 5.5 CFM/W 7 in. diameter
Broan BCSEK130WW 150.0 CFM N/A CFM Unpublished 5.5 CFM/W 7 in. diameter
Broan BCSEK136BL 150.0 CFM N/A CFM Unpublished 5.5 CFM/W 7 in. diameter
Broan BCSEK136SS 150.0 CFM N/A CFM Unpublished 5.5 CFM/W 7 in. diameter
Broan BCSEK136WW 150.0 CFM N/A CFM Unpublished 5.5 CFM/W 7 in. diameter
Broan GLA1243SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1243WW 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1303BL 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1303SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1303WW 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1363BL 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1363SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1363WW 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1423BL 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1423SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA1423WW 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA2303BLS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA2303SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA2303WW 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA2363BLS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan GLA2363SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan MTR1303BL 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan MTR1303BLS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan MTR1303SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan MTR1303WW 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan MTR1363SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan MTR2303SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan MTR2303WW 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan MTR2363SS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 7 in. diameter
Broan-Nutone PTE1115RK 150.0 CFM 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF 150.0 CFM 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan-Nutone PTEL1115RK 150.0 CFM 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan PTE1115RKY 150.0 CFM 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan QTXE110150DC 150.0 CFM 147.8 CFM Unpublished 11.0 CFM/W 6 in. diameter

Who should avoid or adjust scope around ENERGY STAR Bathroom Exhaust Fans — Models 691–805?

Choosing ENERGY STAR Bathroom Exhaust Fans — Models 691–805 depends directly on home age, plumbing drain access, soil clay behavior, and licensing scope; no single remodeling approach fits every household budget or structural condition.

Limitations & Who Should Skip

  • Skip DIY fixture or slab shortcuts if pre-1978 lead paint (>6 sq ft) under EPA 40 CFR 745 or structural wall bowing >=2 in applies.
  • Original Medicare Parts A and B reimburse $0 toward residential bathroom construction under federal Medicare rules; confirm grants beforehand.
  • Commercial contractor quotes multiply raw BLS base wages by overhead, licensing bond, workers' comp, and permit fees.

Best-Fit Homeowner Profiles

  • Best for bid verification: Homeowners comparing ENERGY STAR Bathroom Exhaust Fans — Models 691–805 against 2025 BLS trade hourly rates and official state licensing portals before signing contracts.
  • Who should choose permitted upgrades: Owners planning zero-threshold curbless ADA conversions or permanent IRC R702.4.2 tile systems.
  • Ideal for slope & drainage audits: Property owners cross-checking EPA WaterSense specs and USDA clay data to reject inflated whole-house sales pitches.

What key rules and numbers govern ENERGY STAR Bathroom Exhaust Fans — Models 691–805?

Questions below summarize primary US agency datasets, statutory limits, and IRC, IPC, or NEC compliance rules affecting ENERGY STAR Bathroom Exhaust Fans — Models 691–805.

Do bathrooms need an exhaust fan?

Yes. Residential building codes (IRC M1505 / ASHRAE 62.2) require every bathroom containing a bathtub or shower to provide mechanical exhaust ventilation delivering at least 50 CFM intermittent or 20 CFM continuous airflow vented directly to the exterior—never terminating into an attic soffit or unvented chase.

How to tell if a bathroom exhaust fan is working properly?

Test draw with a single square of toilet tissue held under the grille; if suction cannot hold the paper or mirror condensation lingers more than 15 minutes, measure attic duct diameter. Corrugated 3-inch flex ducts commonly choke 0.1 in. w.g. blower output by 35% to 55% compared with 4-inch smooth rigid metal ducts.

Do I need an electrician to install an extractor fan in my bathroom?

When swapping an existing ceiling fan housing onto a working wall switch, basic mechanical replacement is often straightforward, whereas running a new dedicated circuit, wiring GFCI branch protection under IRC E3902.1, or adding a fan-heater load exceeding 15 amps requires a licensed electrician and municipal electrical permit.

What to avoid when renovating a bathroom?

Avoid installing paper-faced drywall behind wet shower tile (violates IRC R702.4.2), venting exhaust fans into unvented attics or 3-inch kinked flex duct, skipping pre-1978 EPA Lead RRP containment above 6 sq ft, and signing unverified bids before checking official state contractor licensing portals.

What official benchmarks establish ENERGY STAR Bathroom Exhaust Fans , Models 691-805 thresholds here?

GradeMark anchors ENERGY STAR Bathroom Exhaust Fans , Models 691-805 on primary agency metrics including Models Shown (115) and Total Catalog (1,145). This catalog slice lists 115 ENERGY STAR certified bathroom exhaust fans (Models 691-805 out of 1,145 nationwide) with tested airflow. All inputs come from verifiable US government records or OEM spec sheets.

How does Models Shown interact with local IRC, IPC, and NEC residential codes?

For ENERGY STAR Bathroom Exhaust Fans , Models 691-805, federal statutory metrics like Models Shown (115) and Median Efficacy (4.7 CFM/W) operate alongside city-adopted residential IRC, IPC plumbing, and NEC 210.8 / 680.71 electrical inspection schedules rather than commercial 2010 ADA rules.

Which contractor bid checks apply when budgeting ENERGY STAR Bathroom Exhaust Fans , Models 691-805?

Separate Models Shown (115) and Total Catalog (1,145) cleanly inside itemized estimates for ENERGY STAR Bathroom Exhaust Fans , Models 691-805, checking 2021-2026 BLS material Producer Price Index shifts (+33% to +47%) and May 2025 BLS hourly wage baselines.

Who should pause or request an independent PE or permit audit on ENERGY STAR Bathroom Exhaust Fans , Models 691-805?

Pause before paying >30% upfront deposits on ENERGY STAR Bathroom Exhaust Fans , Models 691-805 when contractors refuse written SKU sheets, claim Original Medicare pays ($0 under federal Medicare rules), or omit pre-1978 EPA Lead RRP containment (>6 sq ft).

Can homeowners combine VA SAH/HISA, USDA 504, or IRS Pub 502 with ENERGY STAR Bathroom Exhaust Fans , Models 691-805?

Yes, when pre-approved prior to construction: qualified veterans use VA SAH ($133,042 FY27) or HISA ($6,800/$2,000), age-62+ rural owners check USDA 504 ($10,000), and taxpayers apply IRS Pub 502 medical deductions above 7.5% AGI.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)
  3. Occupational Employment and Wage Statistics (OEWS) State Estimates — SOC 47-1011, 47-2031, 47-2044, 47-2051, 47-2152 — U.S. Bureau of Labor Statistics, May 2025 OEWS State Release (retrieved 2026-11-23)
  4. Producer Price Index (PPI) — Construction Materials & Concrete Series — U.S. Bureau of Labor Statistics, 2021-2026 Monthly PPI Flat Files (retrieved 2026-11-23)
  5. VA Disability Housing Grants (SAH, SHA, HISA) FY 2027 Statutory Limits — U.S. Department of Veterans Affairs, FY 2027 (retrieved 2026-11-23)
  6. 38 CFR Part 17 §§ 17.3100-17.3130 — Home Improvements and Structural Alterations (HISA) — eCFR / Office of the Federal Register, 2026-01-01 (retrieved 2026-11-23)
  7. Direct Single Family Housing Loans and Grants Programs (87 FR 6772 — Section 504) — USDA Rural Housing Service / Federal Register, 87 FR 6772 (retrieved 2026-11-23)
  8. IRS Publication 502: Medical and Dental Expenses (Capital Expenses) — Internal Revenue Service, 2025/2026 (retrieved 2026-11-23)
  9. International Residential Code (IRC R308.4.5, M1505) & International Plumbing Code (IPC 412.3 / ASSE 1016) — International Code Council (Numerical Thresholds Cited Only), 2021/2024 Editions (retrieved 2026-11-23)
  10. 2010 ADA Standards for Accessible Design (28 CFR Part 36, Chapter 6) — U.S. Department of Justice, 2010 Standards (retrieved 2026-11-23)
  11. 40 CFR Part 745 Subpart E — Lead-Based Paint Renovation, Repair, and Painting (RRP) — U.S. EPA / eCFR, 2026-01-01 (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories