Skip to main content
Grant Estimator

High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W)

High-efficacy ECM bathroom fans (>=8.0 CFM/W) engineered for low-wattage 24/7 continuous ASHRAE 62.2 whole-house ventilation.
Direct Reference Summary

High-efficacy ECM bathroom fans (>=8.0 CFM/W) engineered for low-wattage 24/7 continuous ASHRAE 62.2 whole-house ventilation. Compare tested airflow at 0.1 in. and 0.25 in. w.g. static pressure, acoustic sone output, motor efficacy, and rigid duct collar size across 220 featured models below. Compare verified EPA WaterSense and ENERGY STAR certified assemblies filtered from active public registries for High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W) before ordering valves or trim.

Models Listed
220
Full Registry
1,145
Median Efficacy
4.7 CFM/W
IRC M1505 Min
50 CFM
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

How have U.S. plumbing and remodeling material costs shifted from 2021 to 2026?

BLS Producer Price Index trajectories climbed steeply from 349.2 in 2021 to 452.8 through late 2026, setting clear baseline separation between labor pay and supply inflation.

BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Bar trend chart for BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026) across 6 periods (2021 to 2026). First: 349.1; latest: 452.8.BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Unit: idx0.0226.4452.82021: 349.1349.120212022: 385.5385.520222023: 395.0395.020232024: 401.4401.420242025: 424.1424.120252026: 452.8452.82026

How does exhaust duct geometry change static pressure?

Smooth 4-in or 6-in rigid steel ducts terminated outdoors preserve ~82% of rated fan CFM at 0.25 in. w.g., while sagging 3-in attic flex ducts choke airflow below code minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W) records match your engineering filters?

Filter verified government registry entries by threshold category or type a brand, model SKU, or state keyword below to narrow matching records instantaneously.

High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W) — filter or sort verified EPA ENERGY STAR listings
Broan XB110H 110.0 CFM 110.2 CFM 0.1 sones 14.3 CFM/W 6 in. diameter
Delta 80HS 80.0 CFM 59.0 CFM 0.2 sones 11.4 CFM/W 4 in. diameter
DewStop - Breeze Easy BES80 80.0 CFM 84.9 CFM 0.3 sones 16.1 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL80 80.0 CFM 86.6 CFM 0.4 sones 15.7 CFM/W 4 in. diameter
Ortech ODD-70-1 75.0 CFM 62.3 CFM 0.4 sones 16.7 CFM/W 4 in. diameter
Revent RVS80 80.0 CFM 88.8 CFM 0.6 sones 12.6 CFM/W 4 in. diameter
Revent RVSH80 80.0 CFM 88.8 CFM 0.6 sones 12.6 CFM/W 4 in. diameter
Ortech ODD-90-1 95.0 CFM 78.9 CFM 0.7 sones 13.2 CFM/W 4 in. diameter
Delta 50F-LED 50.0 CFM 40.2 CFM 0.7 sones 10.8 CFM/W 4 in. diameter
Delta ITG50 50.0 CFM 40.7 CFM 0.7 sones 12.3 CFM/W 4 in. diameter
Delta ITG50LED 50.0 CFM 40.2 CFM 0.7 sones 10.8 CFM/W 4 in. diameter
Revent RVS110 110.0 CFM 119.2 CFM 0.8 sones 12.3 CFM/W 4 in. diameter
Revent RVSH110 110.0 CFM 119.2 CFM 0.8 sones 12.3 CFM/W 4 in. diameter
Revent RVL80 80.0 CFM 89.0 CFM 0.8 sones 12.0 CFM/W 4 in. diameter
Ortech ODD-110-1 112.0 CFM 94.5 CFM 1.0 sones 11.4 CFM/W 4 in. diameter
DewStop - Breeze Easy BES110 110.0 CFM 116.8 CFM 1.0 sones 11.9 CFM/W 4 in. diameter
Delta 70BT 70.0 CFM 60.0 CFM 1.0 sones 10.6 CFM/W 4 in. diameter
Delta ITG70BT 70.0 CFM 60.0 CFM 1.0 sones 10.6 CFM/W 4 in. diameter
Delta 50F 50.0 CFM 41.3 CFM 1.0 sones 11.6 CFM/W 3 in. diameter
Delta SLM50 50.0 CFM 41.3 CFM 1.0 sones 11.6 CFM/W 3 in. diameter
Hampton Bay 7114-02 50.0 CFM 36.9 CFM 1.0 sones 10.2 CFM/W 3 in. diameter
HomeWerks Worldwide 7114-02-HW 50.0 CFM 36.9 CFM 1.0 sones 10.2 CFM/W 3 in. diameter
Utilitech 7114-02-L 50.0 CFM 36.9 CFM 1.0 sones 10.2 CFM/W 3 in. diameter
DewStop - Breeze Easy BEL110 110.0 CFM 113.6 CFM 1.2 sones 11.2 CFM/W 4 in. diameter
Revent RVL110 110.0 CFM 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVLH110 110.0 CFM 120.2 CFM 1.2 sones 11.3 CFM/W 4 in. diameter
Revent RVL110120130 130.0 CFM 137.2 CFM Unpublished 15.8 CFM/W 6 in. diameter
Revent RVS110120130 130.0 CFM 140.8 CFM Unpublished 16.0 CFM/W 6 in. diameter
Utilitech UTL110120130 130.0 CFM 137.2 CFM Unpublished 15.8 CFM/W 6 in. diameter
Utilitech UTS110120130 130.0 CFM 140.8 CFM Unpublished 16.0 CFM/W 6 in. diameter
Ortech ODD-110HS 113.0 CFM 97.5 CFM Unpublished 11.8 CFM/W 4 in. diameter
Ortech ODD-110HS+MS 113.0 CFM 97.5 CFM Unpublished 11.8 CFM/W 4 in. diameter
Ortech ODD-110S 113.0 CFM 97.5 CFM Unpublished 11.8 CFM/W 4 in. diameter
Broan-Nutone PTE511RK 110.0 CFM 110.8 CFM Unpublished 14.5 CFM/W 6 in. diameter
Broan-Nutone PTE511RK 110.0 CFM 112.0 CFM Unpublished 10.5 CFM/W 4 in. diameter
Broan-Nutone PTE511RK = PTE511H with PTE511RKF 110.0 CFM 110.8 CFM Unpublished 14.5 CFM/W 6 in. diameter
Broan-Nutone PTE511RK = PTE511H with PTE511RKF 110.0 CFM 112.0 CFM Unpublished 10.5 CFM/W 4 in. diameter
Broan-Nutone PTEL511RK 110.0 CFM 112.0 CFM Unpublished 10.5 CFM/W 4 in. diameter
Broan-Nutone PTEL511RK 110.0 CFM 110.8 CFM Unpublished 14.5 CFM/W 6 in. diameter
Broan PTE511RKY 110.0 CFM 110.8 CFM Unpublished 14.5 CFM/W 6 in. diameter
Broan PTE511RKY 110.0 CFM 112.0 CFM Unpublished 10.5 CFM/W 4 in. diameter
Delta SIG80-110 110.0 CFM 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110 110.0 CFM 110.7 CFM Unpublished 10.5 CFM/W 4 in. diameter
Delta SIG80-110D 110.0 CFM 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110D 110.0 CFM 110.7 CFM Unpublished 10.5 CFM/W 4 in. diameter
Delta SIG80-110H 110.0 CFM 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110H 110.0 CFM 110.7 CFM Unpublished 10.5 CFM/W 4 in. diameter
Delta SIG80-110MH 110.0 CFM 110.9 CFM Unpublished 15.3 CFM/W 6 in. diameter
Delta SIG80-110MH 110.0 CFM 110.7 CFM Unpublished 10.5 CFM/W 4 in. diameter
DewStop - Breeze Easy BEL5080110 110.0 CFM 119.5 CFM Unpublished 11.0 CFM/W 4 in. diameter
DewStop - Breeze Easy BES5080110 110.0 CFM 117.0 CFM Unpublished 11.8 CFM/W 4 in. diameter
DewStop - Breeze Easy F300-5080110-W1 110.0 CFM 117.0 CFM Unpublished 11.8 CFM/W 4 in. diameter
Panasonic FV-0511VF1 110.0 CFM 112.9 CFM Unpublished 11.0 CFM/W 4 in. diameter
Panasonic FV-0511VFC1 110.0 CFM 112.9 CFM Unpublished 11.0 CFM/W 4 in. diameter
Panasonic FV-0511VFL1 110.0 CFM 112.2 CFM Unpublished 10.7 CFM/W 4 in. diameter
Panasonic FV-0511VFL1K 110.0 CFM 112.2 CFM Unpublished 10.7 CFM/W 4 in. diameter
Panasonic FV-0511VK3 110.0 CFM 112.9 CFM Unpublished 16.7 CFM/W 6 in. diameter
Panasonic FV-0511VK3 110.0 CFM 111.4 CFM Unpublished 11.4 CFM/W 4 in. diameter
Panasonic FV-0511VKL3 110.0 CFM 114.3 CFM Unpublished 10.8 CFM/W 4 in. diameter
Panasonic FV-0511VKL3 110.0 CFM 114.4 CFM Unpublished 15.7 CFM/W 6 in. diameter
Panasonic FV-0511VKS3 110.0 CFM 112.9 CFM Unpublished 16.7 CFM/W 6 in. diameter
Panasonic FV-0511VKS3 110.0 CFM 111.4 CFM Unpublished 11.4 CFM/W 4 in. diameter
Panasonic FV-0511VKS3S 110.0 CFM 111.9 CFM Unpublished 15.1 CFM/W 6 in. diameter
Panasonic FV-0511VKS3S 110.0 CFM 113.1 CFM Unpublished 10.5 CFM/W 4 in. diameter
Panasonic FV-0511VKSL3 110.0 CFM 114.4 CFM Unpublished 15.7 CFM/W 6 in. diameter
Panasonic FV-0511VKSL3 110.0 CFM 114.3 CFM Unpublished 10.8 CFM/W 4 in. diameter
Panasonic FV-0511VKSL3K 110.0 CFM 111.1 CFM Unpublished 15.6 CFM/W 6 in. diameter
Panasonic FV-0511VQ1 110.0 CFM 114.7 CFM Unpublished 10.7 CFM/W 4 in. diameter
Panasonic FV-0511VQC1 110.0 CFM 114.7 CFM Unpublished 10.7 CFM/W 4 in. diameter
QuFresh FA100X 110.0 CFM N/A CFM Unpublished 8.1 CFM/W 6 in. diameter
QuFresh QUF100X 110.0 CFM N/A CFM Unpublished 8.1 CFM/W 6 in. diameter
Revent BELH8090110 110.0 CFM 120.6 CFM Unpublished 10.9 CFM/W 4 in. diameter
Revent RVS80110 110.0 CFM 121.1 CFM Unpublished 12.0 CFM/W 4 in. diameter
Revent RVSC8095110 110.0 CFM 117.8 CFM Unpublished 11.3 CFM/W 4 in. diameter
Revent RVSH80110 110.0 CFM 121.1 CFM Unpublished 12.0 CFM/W 4 in. diameter
ACIQ ANPD100-3 100.0 CFM 103.8 CFM Unpublished 11.1 CFM/W 4 in. diameter
Broan LP50100DC 100.0 CFM 104.5 CFM Unpublished 10.5 CFM/W 4 in. diameter
Broan LP50100DC=LPDCH with LP50100DCF 100.0 CFM 104.5 CFM Unpublished 10.5 CFM/W 4 in. diameter
CFM TF100-EC 100.0 CFM 103.8 CFM Unpublished 11.1 CFM/W 4 in. diameter
Cyclone CBPD3S100 100.0 CFM 84.7 CFM Unpublished 13.2 CFM/W 4 in. diameter
Cyclone CBPD3S100H 100.0 CFM 84.7 CFM Unpublished 13.2 CFM/W 4 in. diameter
Cyclone CTLD100 100.0 CFM 84.7 CFM Unpublished 13.3 CFM/W 4 in. diameter
Revent RVL8090100 100.0 CFM 109.2 CFM Unpublished 12.5 CFM/W 4 in. diameter
Revent RVS8090100 100.0 CFM 108.5 CFM Unpublished 12.7 CFM/W 4 in. diameter
Utilitech UTL8090100 100.0 CFM 109.2 CFM Unpublished 12.5 CFM/W 4 in. diameter
Utilitech UTS8090100 100.0 CFM 108.5 CFM Unpublished 12.7 CFM/W 4 in. diameter
S&P PCD80XHP 80.0 CFM 84.8 CFM Unpublished 14.4 CFM/W 4 in. diameter
Best HBN536212SS 200.0 CFM N/A CFM 0.0 sones 16.6 CFM/W 10 in. diameter
Best HBN536912SS 200.0 CFM N/A CFM 0.0 sones 16.6 CFM/W 10 in. diameter
Best HBN542912SS 200.0 CFM N/A CFM 0.0 sones 16.6 CFM/W 10 in. diameter
Best HBN548212SS 200.0 CFM N/A CFM 0.0 sones 16.6 CFM/W 10 in. diameter
Best HBN548912SS 200.0 CFM N/A CFM 0.0 sones 16.6 CFM/W 10 in. diameter
Best HBN554212SS 200.0 CFM N/A CFM 0.0 sones 16.6 CFM/W 10 in. diameter
Best HBN560212SS 200.0 CFM N/A CFM 0.0 sones 16.6 CFM/W 10 in. diameter
Best HBN566212SS 200.0 CFM N/A CFM 0.0 sones 16.6 CFM/W 10 in. diameter
Delta SMT130 130.0 CFM 126.3 CFM 0.0 sones 11.4 CFM/W 6 in. diameter
Best HBN223012SS 180.0 CFM N/A CFM 0.1 sones 14.2 CFM/W 10 in. diameter
Best HBN223612SS 180.0 CFM N/A CFM 0.1 sones 14.2 CFM/W 10 in. diameter
Best HBN224812SS 180.0 CFM N/A CFM 0.1 sones 14.2 CFM/W 10 in. diameter
Broan XB110=XB000HwithXB110F 110.0 CFM 110.2 CFM 0.1 sones 14.3 CFM/W 6 in. diameter
Broan XB80=XB00HwithXB80F 80.0 CFM 80.0 CFM 0.1 sones 13.8 CFM/W 6 in. diameter
Broan XB50=XB00HwithXB50F 50.0 CFM 57.8 CFM 0.2 sones 11.8 CFM/W 6 in. diameter
Broan XB50L1 50.0 CFM 55.6 CFM 0.2 sones 11.8 CFM/W 6 in. diameter
Delta 150F 150.0 CFM 150.5 CFM 0.3 sones 8.9 CFM/W 6 in. diameter
Broan (Canada) XB110L1 110.0 CFM 110.3 CFM 0.3 sones 12.6 CFM/W 6 in. diameter
Broan XB110 110.0 CFM 110.2 CFM 0.3 sones 14.3 CFM/W 6 in. diameter
Broan XB110HL1 110.0 CFM 110.3 CFM 0.3 sones 12.6 CFM/W 6 in. diameter
Delta SIG110 110.0 CFM 96.5 CFM 0.3 sones 9.0 CFM/W 4 in. diameter
Pennbarry ZQ110 6" 110.0 CFM N/A CFM 0.3 sones 13.1 CFM/W 8 in. diameter
Broan XB80 80.0 CFM 80.0 CFM 0.3 sones 13.8 CFM/W 6 in. diameter
Broan XB80 80.0 CFM 80.0 CFM 0.3 sones 10.5 CFM/W 4 in. diameter
Broan XB80=XB00HwithXB80F 80.0 CFM 80.0 CFM 0.3 sones 10.5 CFM/W 4 in. diameter
Delta SIG80 80.0 CFM 80.4 CFM 0.3 sones 9.6 CFM/W 4 in. diameter
Pennbarry ZQ80-4" 80.0 CFM N/A CFM 0.3 sones 10.2 CFM/W 8 in. diameter
Broan XB50 50.0 CFM 57.8 CFM 0.3 sones 11.8 CFM/W 6 in. diameter
Broan XB50 50.0 CFM 50.1 CFM 0.3 sones 9.8 CFM/W 4 in. diameter
Broan XB50=XB00HwithXB50F 50.0 CFM 50.1 CFM 0.3 sones 9.8 CFM/W 4 in. diameter
Broan XB50L1 50.0 CFM 50.5 CFM 0.3 sones 9.4 CFM/W 4 in. diameter
Panasonic RG-E130A 130.0 CFM 132.0 CFM 0.4 sones 12.5 CFM/W 6 in. diameter
Delta 110LED-ADJ 110.0 CFM 98.1 CFM 0.4 sones 8.3 CFM/W 4 in. diameter
Delta 150LED-ADJ 150.0 CFM 155.0 CFM 0.5 sones 8.8 CFM/W 6 in. diameter
Panasonic Eco Solutions RG-E110THA 110.0 CFM 110.3 CFM 0.5 sones 9.9 CFM/W 4 in. diameter
Panasonic RG-S80LHA 80.0 CFM 83.9 CFM 0.5 sones 9.3 CFM/W 4 in. diameter
Revent RVS150 150.0 CFM 155.8 CFM 0.7 sones 12.0 CFM/W 6 in. diameter
Revent RVSH150 150.0 CFM 155.8 CFM 0.7 sones 12.0 CFM/W 6 in. diameter
KORA SBF90DC-MS 98.1 CFM N/A CFM 0.7 sones 10.7 CFM/W 4 in. diameter
Revent RVL150 150.0 CFM 152.1 CFM 0.8 sones 12.1 CFM/W 6 in. diameter
Revent RVLH150 150.0 CFM 152.1 CFM 0.8 sones 12.1 CFM/W 6 in. diameter
Delta 80F 80.0 CFM 68.8 CFM 0.8 sones 9.5 CFM/W 4 in. diameter
Delta 80F-DGL 80.0 CFM 68.8 CFM 0.8 sones 9.5 CFM/W 4 in. diameter
Delta GBR80 80.0 CFM 68.8 CFM 0.8 sones 9.5 CFM/W 4 in. diameter
ACIQ AEPD150SC 150.0 CFM 130.3 CFM 0.9 sones 11.4 CFM/W 6 in. diameter
Delta PRO200 200.0 CFM 163.6 CFM 1.0 sones 11.4 CFM/W 6 in. diameter
Utilitech 7116-02 150.0 CFM 123.8 CFM 1.0 sones 8.1 CFM/W 6 in. diameter
Hampton Bay 1001357397 50.0 CFM 47.0 CFM 1.0 sones 8.1 CFM/W 3 in. diameter
Revent RVS50 50.0 CFM 50.0 CFM 1.0 sones 9.1 CFM/W 4 in. diameter
Revent RVSH50 50.0 CFM 50.0 CFM 1.0 sones 9.1 CFM/W 4 in. diameter
Tech Drive TD-BF-13 50.0 CFM 47.0 CFM 1.0 sones 8.1 CFM/W 3 in. diameter
VENTECHLATION BPT12-13E 50.0 CFM 47.0 CFM 1.0 sones 8.1 CFM/W 3 in. diameter
Panasonic Eco Solutions RG-N110LHA 110.0 CFM 111.2 CFM 1.1 sones 9.5 CFM/W 4 in. diameter
KORA SBF160DC-MS 161.6 CFM N/A CFM 1.3 sones 8.7 CFM/W 4 in. diameter
Delta ITG80 80.0 CFM 68.3 CFM 1.3 sones 8.4 CFM/W 4 in. diameter
Utilitech UTLDR110 110.0 CFM 119.0 CFM 1.4 sones 9.4 CFM/W 4 in. diameter
Utilitech UTLDS110 110.0 CFM 113.4 CFM 1.4 sones 8.9 CFM/W 4 in. diameter
Delta 100HS 100.0 CFM 84.1 CFM 1.4 sones 8.1 CFM/W 4 in. diameter
Delta GBR100LED-DECOR 100.0 CFM 75.0 CFM 1.5 sones 8.4 CFM/W 4 in. diameter
Loren Cook Company GCVF 100 127.0 CFM N/A CFM 1.7 sones 11.1 CFM/W 5.94 in. diameter
Loren Cook Company GCVF 300 167.0 CFM N/A CFM 1.9 sones 9.9 CFM/W 8 x 6 in. rectangular
Delta SMT150-200 200.0 CFM 203.4 CFM Unpublished 8.7 CFM/W 6 in. diameter
Delta SMT150-200LED 200.0 CFM 204.9 CFM Unpublished 10.3 CFM/W 6 in. diameter
Revent RVSC120140160 160.0 CFM 164.7 CFM Unpublished 10.9 CFM/W 6 in. diameter
Broan-Nutone PTE1115RK 150.0 CFM 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan-Nutone PTE1115RK = PTE1115H with PTE1115RKF 150.0 CFM 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan-Nutone PTEL1115RK 150.0 CFM 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan PTE1115RKY 150.0 CFM 154.4 CFM Unpublished 14.2 CFM/W 6 in. diameter
Broan QTXE110150DC 150.0 CFM 147.8 CFM Unpublished 11.0 CFM/W 6 in. diameter
Broan QTXE110150DC=QTXEDCH with QTXE110150DCF 150.0 CFM 147.8 CFM Unpublished 11.0 CFM/W 6 in. diameter
Broan QTXE110150DCL 150.0 CFM 147.8 CFM Unpublished 11.0 CFM/W 6 in. diameter
Broan QTXE110150DCL=QTXEDCLH with QTXE110150DCLF 150.0 CFM 147.8 CFM Unpublished 11.0 CFM/W 6 in. diameter
Delta SMT150D 150.0 CFM 150.5 CFM Unpublished 8.9 CFM/W 6 in. diameter
Fantech S110-130-150 (484315) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech S110-130-150L (484316) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150H (484317) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150LH (484318) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150LHO (484319) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
Panasonic FV-1115VK3 150.0 CFM 158.7 CFM Unpublished 13.7 CFM/W 6 in. diameter
Panasonic FV-1115VK3 with FV-VS15VK1 150.0 CFM 158.7 CFM Unpublished 13.7 CFM/W 6 in. diameter
Panasonic FV-1115VKL3 150.0 CFM 152.1 CFM Unpublished 12.2 CFM/W 6 in. diameter
Panasonic FV-1115VKL3 with FV-VS15VK1 150.0 CFM 152.1 CFM Unpublished 12.2 CFM/W 6 in. diameter
Panasonic FV-1115VQ1 150.0 CFM 154.7 CFM Unpublished 12.9 CFM/W 6 in. diameter
Panasonic FV-1115VQL1 150.0 CFM 146.2 CFM Unpublished 11.7 CFM/W 6 in. diameter
Panasonic FV-1315RQ2 150.0 CFM 143.3 CFM Unpublished 10.6 CFM/W 6 in. diameter
Panasonic RG-C1315A 150.0 CFM 143.3 CFM Unpublished 10.6 CFM/W 6 in. diameter
Panasonic RG-C1315LA 150.0 CFM 143.3 CFM Unpublished 10.6 CFM/W 6 in. diameter
S&P PCD150 150.0 CFM 159.6 CFM Unpublished 10.6 CFM/W 6 in. diameter
ACIQ AEPD140-3 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
CFM TF140-EC 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
Haier QVE110DTWW 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
Ortech ODD-110-18PB 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
S&P PCD110XP 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
AUPU V6-13H 130.0 CFM 135.8 CFM Unpublished 8.9 CFM/W 4 in. diameter
AUPU V6-13HL 130.0 CFM 138.7 CFM Unpublished 8.1 CFM/W 4 in. diameter
AUPU V6-13HML 130.0 CFM 138.7 CFM Unpublished 8.1 CFM/W 4 in. diameter
AUPU V6-13HS 130.0 CFM 135.8 CFM Unpublished 8.9 CFM/W 4 in. diameter
Delta SMT130H 130.0 CFM 126.3 CFM Unpublished 11.4 CFM/W 6 in. diameter
Delta SMT130M 130.0 CFM 126.3 CFM Unpublished 11.4 CFM/W 6 in. diameter
Best HBN53696SS 120.0 CFM N/A CFM Unpublished 13.2 CFM/W 8 in. diameter
AUPU B6-11HF 110.0 CFM 89.5 CFM Unpublished 9.7 CFM/W 4 in. diameter
AUPU B6-11HL1 110.0 CFM 87.2 CFM Unpublished 9.7 CFM/W 4 in. diameter
AUPU B6-11HR 110.0 CFM 87.2 CFM Unpublished 9.7 CFM/W 4 in. diameter
AUPU BF6-S13C 110.0 CFM 89.5 CFM Unpublished 9.7 CFM/W 4 in. diameter
AUPU BF6-S13CL 110.0 CFM 87.2 CFM Unpublished 9.7 CFM/W 4 in. diameter
Broan AE50110DC 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DC = A000HFKT with AE50110DCF 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DC = A000HFKTC WITH AE50110DCF 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DC = A000HFNF with AE50110DCF 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DCL 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DCS 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan ZB110HL1 110.0 CFM 113.2 CFM Unpublished 16.2 CFM/W 6 in. diameter
Broan ZB110L1 110.0 CFM 113.2 CFM Unpublished 16.2 CFM/W 6 in. diameter
Broan ZB110ML1 110.0 CFM 113.2 CFM Unpublished 16.2 CFM/W 6 in. diameter
Delta 110HLEDNL 110.0 CFM 98.1 CFM Unpublished 8.3 CFM/W 4 in. diameter
Delta ELT50-110 110.0 CFM 112.4 CFM Unpublished 9.3 CFM/W 4 in. diameter
Delta ELT50-110D 110.0 CFM 112.4 CFM Unpublished 9.3 CFM/W 4 in. diameter
Delta ELT50-110DLED 110.0 CFM 113.7 CFM Unpublished 9.6 CFM/W 4 in. diameter
Delta ELT50-110H 110.0 CFM 112.4 CFM Unpublished 9.3 CFM/W 4 in. diameter
Delta ELT50-110HLED 110.0 CFM 113.7 CFM Unpublished 9.6 CFM/W 4 in. diameter
Delta ELT50-110LED 110.0 CFM 113.7 CFM Unpublished 9.6 CFM/W 4 in. diameter
Delta ELT50-110MH 110.0 CFM 112.4 CFM Unpublished 9.3 CFM/W 4 in. diameter
Delta ELT50-110MHLED 110.0 CFM 113.7 CFM Unpublished 9.6 CFM/W 4 in. diameter
Delta ELT80-110 110.0 CFM 96.9 CFM Unpublished 11.5 CFM/W 6 in. diameter
Delta ELT80-110 110.0 CFM 93.7 CFM Unpublished 9.2 CFM/W 4 in. diameter
Delta ELT80-110D 110.0 CFM 93.7 CFM Unpublished 9.2 CFM/W 4 in. diameter
Delta ELT80-110D 110.0 CFM 96.9 CFM Unpublished 11.5 CFM/W 6 in. diameter
Delta ELT80-110DLED 110.0 CFM 92.3 CFM Unpublished 11.9 CFM/W 6 in. diameter
Delta ELT80-110H 110.0 CFM 93.7 CFM Unpublished 9.2 CFM/W 4 in. diameter
Delta ELT80-110H 110.0 CFM 96.9 CFM Unpublished 11.5 CFM/W 6 in. diameter
Delta ELT80-110HLED 110.0 CFM 92.3 CFM Unpublished 11.9 CFM/W 6 in. diameter
Delta ELT80-110LED 110.0 CFM 92.3 CFM Unpublished 11.9 CFM/W 6 in. diameter
Delta ELT80-110MH 110.0 CFM 93.7 CFM Unpublished 9.2 CFM/W 4 in. diameter

Who should avoid or adjust scope around High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W)?

Choosing High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W) depends directly on home age, plumbing drain access, soil clay behavior, and licensing scope; no single remodeling approach fits every household budget or structural condition.

Limitations & Who Should Skip

  • Skip DIY fixture or slab shortcuts if pre-1978 lead paint (>6 sq ft) under EPA 40 CFR 745 or structural wall bowing >=2 in applies.
  • Original Medicare Parts A and B reimburse $0 toward residential bathroom construction under federal Medicare rules; confirm grants beforehand.
  • Commercial contractor quotes multiply raw BLS base wages by overhead, licensing bond, workers' comp, and permit fees.

Best-Fit Homeowner Profiles

  • Best for bid verification: Homeowners comparing High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W) against 2025 BLS trade hourly rates and official state licensing portals before signing contracts.
  • Who should choose permitted upgrades: Owners planning zero-threshold curbless ADA conversions or permanent IRC R702.4.2 tile systems.
  • Ideal for slope & drainage audits: Property owners cross-checking EPA WaterSense specs and USDA clay data to reject inflated whole-house sales pitches.

What key rules and numbers govern High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W)?

Questions below summarize primary US agency datasets, statutory limits, and IRC, IPC, or NEC compliance rules affecting High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W).

Do I need an electrician to install an extractor fan in my bathroom?

When swapping an existing ceiling fan housing onto a working wall switch, basic mechanical replacement is often straightforward, whereas running a new dedicated circuit, wiring GFCI branch protection under IRC E3902.1, or adding a fan-heater load exceeding 15 amps requires a licensed electrician and municipal electrical permit.

Do bathrooms need an exhaust fan?

Yes. Residential building codes (IRC M1505 / ASHRAE 62.2) require every bathroom containing a bathtub or shower to provide mechanical exhaust ventilation delivering at least 50 CFM intermittent or 20 CFM continuous airflow vented directly to the exterior—never terminating into an attic soffit or unvented chase.

How to tell if a bathroom exhaust fan is working properly?

Test draw with a single square of toilet tissue held under the grille; if suction cannot hold the paper or mirror condensation lingers more than 15 minutes, measure attic duct diameter. Corrugated 3-inch flex ducts commonly choke 0.1 in. w.g. blower output by 35% to 55% compared with 4-inch smooth rigid metal ducts.

What to avoid when renovating a bathroom?

Avoid installing paper-faced drywall behind wet shower tile (violates IRC R702.4.2), venting exhaust fans into unvented attics or 3-inch kinked flex duct, skipping pre-1978 EPA Lead RRP containment above 6 sq ft, and signing unverified bids before checking official state contractor licensing portals.

What official benchmarks establish High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W) thresholds here?

GradeMark anchors High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W) on primary agency metrics including Models Listed (220) and Full Registry (1,145). High-efficacy ECM bathroom fans (>=8.0 CFM/W) engineered for low-wattage 24/7 continuous ASHRAE 62.2 whole-house ventilation. Compare. All inputs come from verifiable US government records or OEM spec sheets.

How does Models Listed interact with local IRC, IPC, and NEC residential codes?

For High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W), federal statutory metrics like Models Listed (220) and Median Efficacy (4.7 CFM/W) operate alongside city-adopted residential IRC, IPC plumbing, and NEC 210.8 / 680.71 electrical inspection schedules rather than commercial 2010 ADA rules.

Which contractor bid checks apply when budgeting High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W)?

Separate Models Listed (220) and Full Registry (1,145) cleanly inside itemized estimates for High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W), checking 2021-2026 BLS material Producer Price Index shifts (+33% to +47%) and May 2025 BLS hourly wage baselines.

Who should pause or request an independent PE or permit audit on High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W)?

Pause before paying >30% upfront deposits on High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W) when contractors refuse written SKU sheets, claim Original Medicare pays ($0 under federal Medicare rules), or omit pre-1978 EPA Lead RRP containment (>6 sq ft).

Can homeowners combine VA SAH/HISA, USDA 504, or IRS Pub 502 with High-Efficacy Continuous ASHRAE 62.2 Fans (>=8 CFM/W)?

Yes, when pre-approved prior to construction: qualified veterans use VA SAH ($133,042 FY27) or HISA ($6,800/$2,000), age-62+ rural owners check USDA 504 ($10,000), and taxpayers apply IRS Pub 502 medical deductions above 7.5% AGI.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)
  3. Occupational Employment and Wage Statistics (OEWS) State Estimates — SOC 47-1011, 47-2031, 47-2044, 47-2051, 47-2152 — U.S. Bureau of Labor Statistics, May 2025 OEWS State Release (retrieved 2026-11-23)
  4. Producer Price Index (PPI) — Construction Materials & Concrete Series — U.S. Bureau of Labor Statistics, 2021-2026 Monthly PPI Flat Files (retrieved 2026-11-23)
  5. VA Disability Housing Grants (SAH, SHA, HISA) FY 2027 Statutory Limits — U.S. Department of Veterans Affairs, FY 2027 (retrieved 2026-11-23)
  6. 38 CFR Part 17 §§ 17.3100-17.3130 — Home Improvements and Structural Alterations (HISA) — eCFR / Office of the Federal Register, 2026-01-01 (retrieved 2026-11-23)
  7. Direct Single Family Housing Loans and Grants Programs (87 FR 6772 — Section 504) — USDA Rural Housing Service / Federal Register, 87 FR 6772 (retrieved 2026-11-23)
  8. IRS Publication 502: Medical and Dental Expenses (Capital Expenses) — Internal Revenue Service, 2025/2026 (retrieved 2026-11-23)
  9. International Residential Code (IRC R308.4.5, M1505) & International Plumbing Code (IPC 412.3 / ASSE 1016) — International Code Council (Numerical Thresholds Cited Only), 2021/2024 Editions (retrieved 2026-11-23)
  10. 2010 ADA Standards for Accessible Design (28 CFR Part 36, Chapter 6) — U.S. Department of Justice, 2010 Standards (retrieved 2026-11-23)
  11. 40 CFR Part 745 Subpart E — Lead-Based Paint Renovation, Repair, and Painting (RRP) — U.S. EPA / eCFR, 2026-01-01 (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories