Skip to main content
Grant Estimator

ENERGY STAR Bathroom Exhaust Fans — Models 116–230

Catalog section (Models 116–230 of 1,145 total certified blowers) from U.S. EPA ENERGY STAR dataset 8dv7-nngq.
Direct Reference Summary

This catalog slice lists 115 ENERGY STAR certified bathroom exhaust fans (Models 116-230 out of 1,145 nationwide) with tested airflow at 0.1 in. and 0.25 in. w.g., acoustic sones (fleet median 1.0 sones), and motor efficacy (median 4.7 CFM/W). Compare verified EPA WaterSense and ENERGY STAR certified assemblies filtered from active public registries for ENERGY STAR Bathroom Exhaust Fans — Models 116–230 before ordering valves or trim.

Models Shown
115
Total Catalog
1,145
Median Efficacy
4.7 CFM/W
Median CFM
110 CFM
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

How have U.S. plumbing and remodeling material costs shifted from 2021 to 2026?

BLS Producer Price Index trajectories climbed steeply from 349.2 in 2021 to 452.8 through late 2026, setting clear baseline separation between labor pay and supply inflation.

BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Bar trend chart for BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026) across 6 periods (2021 to 2026). First: 349.1; latest: 452.8.BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Unit: idx0.0226.4452.82021: 349.1349.120212022: 385.5385.520222023: 395.0395.020232024: 401.4401.420242025: 424.1424.120252026: 452.8452.82026

How does exhaust duct geometry change static pressure?

Smooth 4-in or 6-in rigid steel ducts terminated outdoors preserve ~82% of rated fan CFM at 0.25 in. w.g., while sagging 3-in attic flex ducts choke airflow below code minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which ENERGY STAR Bathroom Exhaust Fans — Models 116–230 records match your engineering filters?

Filter verified government registry entries by threshold category or type a brand, model SKU, or state keyword below to narrow matching records instantaneously.

ENERGY STAR fan Models 116–230 — filter by acoustic tier or search by brand
Greenheck SP-A110 120.0 CFM 98.0 CFM 0.1 sones 6.2 CFM/W 6 x 8 in. rectangular
Broan XB110=XB000HwithXB110F 110.0 CFM 110.2 CFM 0.1 sones 14.3 CFM/W 6 in. diameter
Broan XB80=XB00HwithXB80F 80.0 CFM 80.0 CFM 0.1 sones 13.8 CFM/W 6 in. diameter
Greenheck SP-A70 70.0 CFM 54.0 CFM 0.1 sones 5.1 CFM/W 6 in. diameter
Cyclone CBP80 80.0 CFM 62.6 CFM 0.2 sones 4.9 CFM/W 4 in. diameter
Ortech ODC-8003 80.0 CFM 62.6 CFM 0.2 sones 4.9 CFM/W 4 in. diameter
QuFresh BC80 80.0 CFM 62.6 CFM 0.2 sones 4.9 CFM/W 4 in. diameter
Broan XB50=XB00HwithXB50F 50.0 CFM 57.8 CFM 0.2 sones 11.8 CFM/W 6 in. diameter
Broan XB50L1 50.0 CFM 55.6 CFM 0.2 sones 11.8 CFM/W 6 in. diameter
Delta 150F 150.0 CFM 150.5 CFM 0.3 sones 8.9 CFM/W 6 in. diameter
Kaze Appliance SEP120 120.0 CFM 94.2 CFM 0.3 sones 4.2 CFM/W 6 in. diameter
S&P PC110XP 120.0 CFM 94.2 CFM 0.3 sones 4.2 CFM/W 6 in. diameter
Broan (Canada) XB110L1 110.0 CFM 110.3 CFM 0.3 sones 12.6 CFM/W 6 in. diameter
Broan XB110 110.0 CFM 110.2 CFM 0.3 sones 14.3 CFM/W 6 in. diameter
Broan XB110HL1 110.0 CFM 110.3 CFM 0.3 sones 12.6 CFM/W 6 in. diameter
Delta SIG110 110.0 CFM 96.5 CFM 0.3 sones 9.0 CFM/W 4 in. diameter
Pennbarry ZQ110 6" 110.0 CFM N/A CFM 0.3 sones 13.1 CFM/W 8 in. diameter
Broan RB80 80.0 CFM 63.1 CFM 0.3 sones 3.0 CFM/W 4 in. diameter
Broan RB80L1 80.0 CFM 61.2 CFM 0.3 sones 2.9 CFM/W 4 in. diameter
Broan XB80 80.0 CFM 80.0 CFM 0.3 sones 13.8 CFM/W 6 in. diameter
Broan XB80 80.0 CFM 80.0 CFM 0.3 sones 10.5 CFM/W 4 in. diameter
Broan XB80=XB00HwithXB80F 80.0 CFM 80.0 CFM 0.3 sones 10.5 CFM/W 4 in. diameter
Delta SIG80 80.0 CFM 80.4 CFM 0.3 sones 9.6 CFM/W 4 in. diameter
Nektra 33003852 80.0 CFM 68.5 CFM 0.3 sones 3.6 CFM/W 4 in. diameter
Pennbarry ZQ80-4" 80.0 CFM N/A CFM 0.3 sones 10.2 CFM/W 8 in. diameter
Wintek BPT15B-80H2 80.0 CFM 68.5 CFM 0.3 sones 3.6 CFM/W 4 in. diameter
Tech Drive TD-BF-06 70.0 CFM 60.4 CFM 0.3 sones 4.6 CFM/W 4 in. diameter
Win Air BPT14-13E 70.0 CFM 60.4 CFM 0.3 sones 4.6 CFM/W 4 in. diameter
Tech Drive TD-BF-06-plus 60.0 CFM 51.5 CFM 0.3 sones 3.7 CFM/W 4 in. diameter
Air King LEDAK50 50.0 CFM 35.0 CFM 0.3 sones 4.4 CFM/W 4 in. diameter
Broan XB50 50.0 CFM 57.8 CFM 0.3 sones 11.8 CFM/W 6 in. diameter
Broan XB50 50.0 CFM 50.1 CFM 0.3 sones 9.8 CFM/W 4 in. diameter
Broan XB50=XB00HwithXB50F 50.0 CFM 50.1 CFM 0.3 sones 9.8 CFM/W 4 in. diameter
Broan XB50L1 50.0 CFM 50.5 CFM 0.3 sones 9.4 CFM/W 4 in. diameter
Panasonic RG-E130A 130.0 CFM 132.0 CFM 0.4 sones 12.5 CFM/W 6 in. diameter
Broan QTXEG110 110.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG110 = QTXEGH with QTXEG110F 110.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG110S 110.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG110S = QTXEGSH with QTXEG110SF 110.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG110SX 110.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG110SX = QTXEGSH with QTXEG110SFX 110.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG110X 110.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG110X = QTXEGH with QTXEG110FX 110.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan RB110 110.0 CFM 91.0 CFM 0.4 sones 3.7 CFM/W 4 in. diameter
Delta 110LED-ADJ 110.0 CFM 98.1 CFM 0.4 sones 8.3 CFM/W 4 in. diameter
Nutone RN110 110.0 CFM 91.0 CFM 0.4 sones 3.7 CFM/W 4 in. diameter
Dayton 3DPE4B 90.0 CFM N/A CFM 0.4 sones 5.5 CFM/W 6 in. diameter
Greenheck SP-A90 90.0 CFM 80.0 CFM 0.4 sones 5.5 CFM/W 6 in. diameter
AERO PURE ABF80G15W 80.0 CFM 62.9 CFM 0.4 sones 4.7 CFM/W 4 in. diameter
AERO PURE ABF80G16W 80.0 CFM 62.9 CFM 0.4 sones 4.7 CFM/W 4 in. diameter
AUPU AV08A1 80.0 CFM 62.9 CFM 0.4 sones 4.7 CFM/W 4 in. diameter
Broan QTXEG080 80.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG080 = QTXEGH with QTXEG080F 80.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG080X 80.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
Broan QTXEG080X = QTXEGH with QTXEG080FX 80.0 CFM 85.6 CFM 0.4 sones 4.7 CFM/W 6 in. diameter
VOTATEC VO-FN4W25-AC-80 80.0 CFM 66.3 CFM 0.4 sones 3.5 CFM/W 4 in. diameter
Wintek BPT15B-80H1 80.0 CFM 66.3 CFM 0.4 sones 3.5 CFM/W 4 in. diameter
KORA SBF70N 76.5 CFM N/A CFM 0.4 sones 3.8 CFM/W 4 in. diameter
Dayton 3DPE2 63.0 CFM N/A CFM 0.4 sones 4.0 CFM/W 6 in. diameter
Greenheck SP-B50 63.0 CFM N/A CFM 0.4 sones 4.0 CFM/W 6 in. diameter
ACIQ ANP50 50.0 CFM 42.3 CFM 0.4 sones 4.0 CFM/W 4 in. diameter
ACIQ AP50 50.0 CFM 42.3 CFM 0.4 sones 3.3 CFM/W 4 in. diameter
Cyclone CBP50 50.0 CFM 42.3 CFM 0.4 sones 4.0 CFM/W 4 in. diameter
Ortech ODE-5004 50.0 CFM 43.6 CFM 0.4 sones 3.4 CFM/W 4 in. diameter
S&P PC50XP 50.0 CFM 42.3 CFM 0.4 sones 4.0 CFM/W 4 in. diameter
ACIQ AEP150 150.0 CFM 123.8 CFM 0.5 sones 4.6 CFM/W 6 in. diameter
Anzzi EF-AZ104WH 150.0 CFM 123.8 CFM 0.5 sones 4.6 CFM/W 6 in. diameter
Anzzi EF-AZ105WH 150.0 CFM 123.8 CFM 0.5 sones 4.6 CFM/W 6 in. diameter
Cyclone ESCBP150 150.0 CFM 123.8 CFM 0.5 sones 4.6 CFM/W 6 in. diameter
Delta 150LED-ADJ 150.0 CFM 155.0 CFM 0.5 sones 8.8 CFM/W 6 in. diameter
Kaze Appliance SEP150 150.0 CFM 123.8 CFM 0.5 sones 4.6 CFM/W 6 in. diameter
Ortech OD-1505PB 150.0 CFM 123.8 CFM 0.5 sones 4.6 CFM/W 6 in. diameter
S&P PC150XP 150.0 CFM 123.8 CFM 0.5 sones 4.6 CFM/W 6 in. diameter
Dayton 5AE70B 120.0 CFM N/A CFM 0.5 sones 6.2 CFM/W 6 x 8 in. rectangular
Panasonic Eco Solutions RG-E110THA 110.0 CFM 110.3 CFM 0.5 sones 9.9 CFM/W 4 in. diameter
Kaze Appliance SEP120 100.0 CFM 83.8 CFM 0.5 sones 3.6 CFM/W 4 in. diameter
Air King AK80LS6 80.0 CFM 59.6 CFM 0.5 sones 4.7 CFM/W 6 in. diameter
Air King AK80LS6H 80.0 CFM 59.6 CFM 0.5 sones 4.7 CFM/W 6 in. diameter
Panasonic RG-S80LHA 80.0 CFM 83.9 CFM 0.5 sones 9.3 CFM/W 4 in. diameter
Dayton 1UBH6B 70.0 CFM N/A CFM 0.5 sones 4.4 CFM/W 6 in. diameter
Greenheck SP-B70 70.0 CFM 54.0 CFM 0.5 sones 4.4 CFM/W 6 in. diameter
Air King AK50S 50.0 CFM 41.1 CFM 0.5 sones 4.1 CFM/W 4 in. diameter
Broan AE50 50.0 CFM 51.9 CFM 0.5 sones 3.5 CFM/W 4 in. diameter
Broan AE50=A000HF2WITHAE50F 50.0 CFM 51.9 CFM 0.5 sones 3.5 CFM/W 4 in. diameter
Broan AE50 = A000HFKTC WITH AE50F1 50.0 CFM 51.9 CFM 0.5 sones 3.5 CFM/W 4 in. diameter
Broan AE50=A000HFKTwithAE50F1 50.0 CFM 51.9 CFM 0.5 sones 3.5 CFM/W 4 in. diameter
Broan AE50=A000HFNFwithAE50F1 50.0 CFM 51.9 CFM 0.5 sones 3.5 CFM/W 4 in. diameter
Broan AE50=A000HFwithAE50F 50.0 CFM 51.9 CFM 0.5 sones 3.5 CFM/W 4 in. diameter
Broan AE50=HPIVFNwithAE50F 50.0 CFM 51.9 CFM 0.5 sones 3.5 CFM/W 4 in. diameter
Ortech ODC-9006 90.0 CFM 73.4 CFM 0.6 sones 5.6 CFM/W 4 in. diameter
ACIQ ANP80 80.0 CFM 62.6 CFM 0.6 sones 4.9 CFM/W 4 in. diameter
AERO PURE ABF80L5OR 80.0 CFM 61.4 CFM 0.6 sones 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SG 80.0 CFM 61.4 CFM 0.6 sones 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SN 80.0 CFM 61.4 CFM 0.6 sones 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5W 80.0 CFM 61.4 CFM 0.6 sones 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L6W 80.0 CFM 61.4 CFM 0.6 sones 4.4 CFM/W 4 in. diameter
Broan AE80 80.0 CFM 74.5 CFM 0.6 sones 3.9 CFM/W 6 in. diameter
Broan AE80K 80.0 CFM 74.5 CFM 0.6 sones 3.9 CFM/W 6 in. diameter
Broan AE80K = A000HFKT with AE80KF 80.0 CFM 74.5 CFM 0.6 sones 3.9 CFM/W 6 in. diameter
Broan AE80K = A000HFKTC WITH AE80KF 80.0 CFM 74.5 CFM 0.6 sones 3.9 CFM/W 6 in. diameter
Broan AE80K = A000HFNF with AE80KF 80.0 CFM 74.5 CFM 0.6 sones 3.9 CFM/W 6 in. diameter
Broan AE80S 80.0 CFM 74.5 CFM 0.6 sones 3.9 CFM/W 6 in. diameter
Broan AE80S = A000HFS with AE80F1 80.0 CFM 74.5 CFM 0.6 sones 3.9 CFM/W 6 in. diameter
Broan AE80SK = A000HSKT with AE80KF 80.0 CFM 74.5 CFM 0.6 sones 3.9 CFM/W 6 in. diameter
Broan AER80K 80.0 CFM 74.5 CFM 0.6 sones 3.9 CFM/W 6 in. diameter
Dayton 1UBH7B 80.0 CFM N/A CFM 0.6 sones 4.4 CFM/W 6 in. diameter
Greenheck SP-B80 80.0 CFM 62.0 CFM 0.6 sones 4.4 CFM/W 6 in. diameter
Hunter 90704 80.0 CFM 70.5 CFM 0.6 sones 3.5 CFM/W 4 in. diameter
Hunter 90705 80.0 CFM 70.5 CFM 0.6 sones 3.5 CFM/W 4 in. diameter
Tech Drive TD-BF-04-plus 80.0 CFM 71.2 CFM 0.6 sones 4.5 CFM/W 4 in. diameter
VENTECHLATION VF-BF-03 80.0 CFM 71.2 CFM 0.6 sones 4.5 CFM/W 4 in. diameter
VENTECHLATION VF-BF-11L 80.0 CFM 71.2 CFM 0.6 sones 4.5 CFM/W 4 in. diameter
Air King BFQ50 50.0 CFM 37.4 CFM 0.6 sones 2.9 CFM/W 4 in. diameter
Air King FR50 50.0 CFM 42.0 CFM 0.6 sones 3.5 CFM/W 4 in. diameter
Air King WM50 50.0 CFM 37.4 CFM 0.6 sones 2.9 CFM/W 4 in. diameter

Who should avoid or adjust scope around ENERGY STAR Bathroom Exhaust Fans — Models 116–230?

Choosing ENERGY STAR Bathroom Exhaust Fans — Models 116–230 depends directly on home age, plumbing drain access, soil clay behavior, and licensing scope; no single remodeling approach fits every household budget or structural condition.

Limitations & Who Should Skip

  • Skip DIY fixture or slab shortcuts if pre-1978 lead paint (>6 sq ft) under EPA 40 CFR 745 or structural wall bowing >=2 in applies.
  • Original Medicare Parts A and B reimburse $0 toward residential bathroom construction under federal Medicare rules; confirm grants beforehand.
  • Commercial contractor quotes multiply raw BLS base wages by overhead, licensing bond, workers' comp, and permit fees.

Best-Fit Homeowner Profiles

  • Best for bid verification: Homeowners comparing ENERGY STAR Bathroom Exhaust Fans — Models 116–230 against 2025 BLS trade hourly rates and official state licensing portals before signing contracts.
  • Who should choose permitted upgrades: Owners planning zero-threshold curbless ADA conversions or permanent IRC R702.4.2 tile systems.
  • Ideal for slope & drainage audits: Property owners cross-checking EPA WaterSense specs and USDA clay data to reject inflated whole-house sales pitches.

What key rules and numbers govern ENERGY STAR Bathroom Exhaust Fans — Models 116–230?

Questions below summarize primary US agency datasets, statutory limits, and IRC, IPC, or NEC compliance rules affecting ENERGY STAR Bathroom Exhaust Fans — Models 116–230.

Do bathrooms need an exhaust fan?

Yes. Residential building codes (IRC M1505 / ASHRAE 62.2) require every bathroom containing a bathtub or shower to provide mechanical exhaust ventilation delivering at least 50 CFM intermittent or 20 CFM continuous airflow vented directly to the exterior—never terminating into an attic soffit or unvented chase.

How to tell if a bathroom exhaust fan is working properly?

Test draw with a single square of toilet tissue held under the grille; if suction cannot hold the paper or mirror condensation lingers more than 15 minutes, measure attic duct diameter. Corrugated 3-inch flex ducts commonly choke 0.1 in. w.g. blower output by 35% to 55% compared with 4-inch smooth rigid metal ducts.

Do I need an electrician to install an extractor fan in my bathroom?

When swapping an existing ceiling fan housing onto a working wall switch, basic mechanical replacement is often straightforward, whereas running a new dedicated circuit, wiring GFCI branch protection under IRC E3902.1, or adding a fan-heater load exceeding 15 amps requires a licensed electrician and municipal electrical permit.

What is the 30% rule for home renovation?

Under residential budgeting practice, homeowners allocate roughly 25% to 30% of project funds as a reserve for hidden subfloor rot, cast-iron drain replacement, and pre-1978 EPA RRP lead containment, while renovation planners avoid investing over 30% of home value in a single room so equity remains balanced under IRS Publication 502 market-value offset rules.

What official benchmarks establish ENERGY STAR Bathroom Exhaust Fans , Models 116-230 thresholds here?

GradeMark anchors ENERGY STAR Bathroom Exhaust Fans , Models 116-230 on primary agency metrics including Models Shown (115) and Total Catalog (1,145). This catalog slice lists 115 ENERGY STAR certified bathroom exhaust fans (Models 116-230 out of 1,145 nationwide) with tested airflow. All inputs come from verifiable US government records or OEM spec sheets.

How does Models Shown interact with local IRC, IPC, and NEC residential codes?

For ENERGY STAR Bathroom Exhaust Fans , Models 116-230, federal statutory metrics like Models Shown (115) and Median Efficacy (4.7 CFM/W) operate alongside city-adopted residential IRC, IPC plumbing, and NEC 210.8 / 680.71 electrical inspection schedules rather than commercial 2010 ADA rules.

Which contractor bid checks apply when budgeting ENERGY STAR Bathroom Exhaust Fans , Models 116-230?

Separate Models Shown (115) and Total Catalog (1,145) cleanly inside itemized estimates for ENERGY STAR Bathroom Exhaust Fans , Models 116-230, checking 2021-2026 BLS material Producer Price Index shifts (+33% to +47%) and May 2025 BLS hourly wage baselines.

Who should pause or request an independent PE or permit audit on ENERGY STAR Bathroom Exhaust Fans , Models 116-230?

Pause before paying >30% upfront deposits on ENERGY STAR Bathroom Exhaust Fans , Models 116-230 when contractors refuse written SKU sheets, claim Original Medicare pays ($0 under federal Medicare rules), or omit pre-1978 EPA Lead RRP containment (>6 sq ft).

Can homeowners combine VA SAH/HISA, USDA 504, or IRS Pub 502 with ENERGY STAR Bathroom Exhaust Fans , Models 116-230?

Yes, when pre-approved prior to construction: qualified veterans use VA SAH ($133,042 FY27) or HISA ($6,800/$2,000), age-62+ rural owners check USDA 504 ($10,000), and taxpayers apply IRS Pub 502 medical deductions above 7.5% AGI.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)
  3. Occupational Employment and Wage Statistics (OEWS) State Estimates — SOC 47-1011, 47-2031, 47-2044, 47-2051, 47-2152 — U.S. Bureau of Labor Statistics, May 2025 OEWS State Release (retrieved 2026-11-23)
  4. Producer Price Index (PPI) — Construction Materials & Concrete Series — U.S. Bureau of Labor Statistics, 2021-2026 Monthly PPI Flat Files (retrieved 2026-11-23)
  5. VA Disability Housing Grants (SAH, SHA, HISA) FY 2027 Statutory Limits — U.S. Department of Veterans Affairs, FY 2027 (retrieved 2026-11-23)
  6. 38 CFR Part 17 §§ 17.3100-17.3130 — Home Improvements and Structural Alterations (HISA) — eCFR / Office of the Federal Register, 2026-01-01 (retrieved 2026-11-23)
  7. Direct Single Family Housing Loans and Grants Programs (87 FR 6772 — Section 504) — USDA Rural Housing Service / Federal Register, 87 FR 6772 (retrieved 2026-11-23)
  8. IRS Publication 502: Medical and Dental Expenses (Capital Expenses) — Internal Revenue Service, 2025/2026 (retrieved 2026-11-23)
  9. International Residential Code (IRC R308.4.5, M1505) & International Plumbing Code (IPC 412.3 / ASSE 1016) — International Code Council (Numerical Thresholds Cited Only), 2021/2024 Editions (retrieved 2026-11-23)
  10. 2010 ADA Standards for Accessible Design (28 CFR Part 36, Chapter 6) — U.S. Department of Justice, 2010 Standards (retrieved 2026-11-23)
  11. 40 CFR Part 745 Subpart E — Lead-Based Paint Renovation, Repair, and Painting (RRP) — U.S. EPA / eCFR, 2026-01-01 (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories