Skip to main content
Grant Estimator

ENERGY STAR Bathroom Exhaust Fans — Models 346–460

Catalog section (Models 346–460 of 1,145 total certified blowers) from U.S. EPA ENERGY STAR dataset 8dv7-nngq.
Direct Reference Summary

This catalog slice lists 115 ENERGY STAR certified bathroom exhaust fans (Models 346-460 out of 1,145 nationwide) with tested airflow at 0.1 in. and 0.25 in. w.g., acoustic sones (fleet median 1.0 sones), and motor efficacy (median 4.7 CFM/W). Compare verified EPA WaterSense and ENERGY STAR certified assemblies filtered from active public registries for ENERGY STAR Bathroom Exhaust Fans — Models 346–460 before ordering valves or trim.

Models Shown
115
Total Catalog
1,145
Median Efficacy
4.7 CFM/W
Median CFM
110 CFM
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

How have U.S. plumbing and remodeling material costs shifted from 2021 to 2026?

BLS Producer Price Index trajectories climbed steeply from 349.2 in 2021 to 452.8 through late 2026, setting clear baseline separation between labor pay and supply inflation.

BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Bar trend chart for BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026) across 6 periods (2021 to 2026). First: 349.1; latest: 452.8.BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Unit: idx0.0226.4452.82021: 349.1349.120212022: 385.5385.520222023: 395.0395.020232024: 401.4401.420242025: 424.1424.120252026: 452.8452.82026

How does exhaust duct geometry change static pressure?

Smooth 4-in or 6-in rigid steel ducts terminated outdoors preserve ~82% of rated fan CFM at 0.25 in. w.g., while sagging 3-in attic flex ducts choke airflow below code minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which ENERGY STAR Bathroom Exhaust Fans — Models 346–460 records match your engineering filters?

Filter verified government registry entries by threshold category or type a brand, model SKU, or state keyword below to narrow matching records instantaneously.

ENERGY STAR fan Models 346–460 — filter by acoustic tier or search by brand
Wintek BPT15B-100H1 100.0 CFM 85.0 CFM 0.9 sones 3.9 CFM/W 4 in. diameter
Wintek BPT15B-100H2 100.0 CFM 84.1 CFM 0.9 sones 4.1 CFM/W 4 in. diameter
Loren Cook Company GC-128 82.0 CFM 63.2 CFM 0.9 sones 2.9 CFM/W 5.94 in. diameter
Revent RVM80 80.0 CFM 68.2 CFM 0.9 sones 4.2 CFM/W 4 in. diameter
Broan-Nutone BE6 60.0 CFM 52.6 CFM 0.9 sones 3.6 CFM/W 4 in. diameter
Broan-Nutone BE6 = BEH with BE6F 60.0 CFM 52.6 CFM 0.9 sones 3.6 CFM/W 4 in. diameter
Broan-Nutone BEL6 60.0 CFM 52.6 CFM 0.9 sones 3.6 CFM/W 4 in. diameter
Broan-Nutone BEL6 = BELH with BEL6F 60.0 CFM 52.6 CFM 0.9 sones 3.6 CFM/W 4 in. diameter
Delta PRO200 200.0 CFM 163.6 CFM 1.0 sones 11.4 CFM/W 6 in. diameter
OREiN OL1700376 160.0 CFM 152.0 CFM 1.0 sones 4.8 CFM/W 6 in. diameter
Tech Drive TD-BF-19 160.0 CFM 138.2 CFM 1.0 sones 4.5 CFM/W 6 in. diameter
VENTECHLATION VF-BF-06 160.0 CFM 138.2 CFM 1.0 sones 4.5 CFM/W 6 in. diameter
Utilitech 7116-02 150.0 CFM 123.8 CFM 1.0 sones 8.1 CFM/W 6 in. diameter
Hampton Bay 7136-02 140.0 CFM 124.4 CFM 1.0 sones 3.9 CFM/W 6 in. diameter
HomeWerks Worldwide 7136-02HW 140.0 CFM 124.4 CFM 1.0 sones 3.9 CFM/W 6 in. diameter
Broan BWPR302SSE 120.0 CFM N/A CFM 1.0 sones 3.2 CFM/W 6 in. diameter
Broan WPR302CSSE 120.0 CFM N/A CFM 1.0 sones 3.2 CFM/W 6 in. diameter
Broan WPR362CSSE 120.0 CFM N/A CFM 1.0 sones 3.2 CFM/W 6 in. diameter
Amazon Basics B089R8S365 110.0 CFM 94.3 CFM 1.0 sones 4.4 CFM/W 4 in. diameter
Broan AE110 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110 = A000HFKT with AE110F1 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110 = A000HFNF with AE110F1 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110K 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110K = A000HFKT with AE110KF 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110K = A000HFKTC with AE110KF 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110K = A000HFNF with AE110KF 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110L 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110LK 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110S 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110S = A000HSKT with AE110F1 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE110SK = A000HSKT with AE110KF 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AER110CCTK 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AER110K 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AER110L 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AER110LK 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AER110S 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AEW110 110.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Delta 110F 110.0 CFM 81.3 CFM 1.0 sones 7.9 CFM/W 4 in. diameter
Delta VFB25ADBT 110.0 CFM 81.3 CFM 1.0 sones 7.9 CFM/W 4 in. diameter
HomeWerks Worldwide 7107-03HW 110.0 CFM 96.0 CFM 1.0 sones 4.1 CFM/W 4 in. diameter
Milano TY-110-E 110.0 CFM 94.5 CFM 1.0 sones 3.9 CFM/W 4 in. diameter
Milano TY-110-ESHL 110.0 CFM 94.2 CFM 1.0 sones 3.9 CFM/W 4 in. diameter
Milano TY-110-ESL 110.0 CFM 94.2 CFM 1.0 sones 3.9 CFM/W 4 in. diameter
Air King AK100LS6 100.0 CFM 82.7 CFM 1.0 sones 3.9 CFM/W 6 in. diameter
Air King AK100LS6H 100.0 CFM 82.7 CFM 1.0 sones 3.9 CFM/W 6 in. diameter
Air King BFC100 100.0 CFM 86.5 CFM 1.0 sones 4.5 CFM/W 4 in. diameter
Air King BFC100H 100.0 CFM 86.5 CFM 1.0 sones 4.5 CFM/W 4 in. diameter
Broan AE100B = A000HFKT with AE100BF1 100.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Broan AE100B = A000HFNF with AE100BF1 100.0 CFM 95.5 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
Good Housekeeping 84005 100.0 CFM 92.3 CFM 1.0 sones 4.5 CFM/W 4 in. diameter
Air King BFC90 90.0 CFM 75.6 CFM 1.0 sones 4.7 CFM/W 4 in. diameter
Air King BFC90H 90.0 CFM 75.6 CFM 1.0 sones 4.7 CFM/W 4 in. diameter
ACIQ AP80 80.0 CFM 71.6 CFM 1.0 sones 3.6 CFM/W 4 in. diameter
Air King AK80H 80.0 CFM 71.4 CFM 1.0 sones 3.8 CFM/W 4 in. diameter
Air King AK80LS1 80.0 CFM 71.4 CFM 1.0 sones 3.8 CFM/W 4 in. diameter
Air King FR80 80.0 CFM 71.4 CFM 1.0 sones 3.8 CFM/W 4 in. diameter
Air King FR80H 80.0 CFM 71.4 CFM 1.0 sones 3.8 CFM/W 4 in. diameter
Broan EZ80 80.0 CFM 65.6 CFM 1.0 sones 3.7 CFM/W 4 in. diameter
Broan LP80 80.0 CFM 65.6 CFM 1.0 sones 3.7 CFM/W 4 in. diameter
Broan LP80=LP80HwithLP80F 80.0 CFM 65.6 CFM 1.0 sones 3.7 CFM/W 4 in. diameter
Canarm CP80 80.0 CFM 71.6 CFM 1.0 sones 3.6 CFM/W 4 in. diameter
Cyclone CT80 80.0 CFM 71.6 CFM 1.0 sones 3.6 CFM/W 4 in. diameter
Cyclone CTP80 80.0 CFM 71.6 CFM 1.0 sones 3.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-02-BN 80.0 CFM 59.5 CFM 1.0 sones 3.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-02-HW 80.0 CFM 59.5 CFM 1.0 sones 3.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80-CTA 80.0 CFM 59.0 CFM 1.0 sones 3.8 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80-HW 80.0 CFM 59.0 CFM 1.0 sones 3.8 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80-RGB 80.0 CFM 59.0 CFM 1.0 sones 3.8 CFM/W 4 in. diameter
Nutone LPN80=LP80HwithLPN80F 80.0 CFM 65.6 CFM 1.0 sones 3.7 CFM/W 4 in. diameter
Panasonic FV-08VRE2 80.0 CFM 66.7 CFM 1.0 sones 4.3 CFM/W 4 in. diameter
QuFresh BQ80 80.0 CFM 71.6 CFM 1.0 sones 3.6 CFM/W 4 in. diameter
Tosca 7117-02-BN 80.0 CFM 59.5 CFM 1.0 sones 3.6 CFM/W 4 in. diameter
Utilitech 7141-80-L 80.0 CFM 59.0 CFM 1.0 sones 3.8 CFM/W 4 in. diameter
HomeWerks Worldwide 7105-10 70.0 CFM 55.7 CFM 1.0 sones 3.4 CFM/W 4 in. diameter
HomeWerks Worldwide 7105-10-MB 70.0 CFM 55.7 CFM 1.0 sones 3.4 CFM/W 4 in. diameter
Nektra 33003851 70.0 CFM 55.7 CFM 1.0 sones 3.4 CFM/W 4 in. diameter
Tuscany 7105-11-M 70.0 CFM 55.7 CFM 1.0 sones 3.4 CFM/W 4 in. diameter
Commercial Electric BF1101 50.0 CFM 45.9 CFM 1.0 sones 5.0 CFM/W 3 in. diameter
Commercial Electric BF1103 50.0 CFM 46.8 CFM 1.0 sones 5.2 CFM/W 3 in. diameter
Commercial Electric BPT13-12EN 50.0 CFM 49.3 CFM 1.0 sones 3.7 CFM/W 3 in. diameter
Hampton Bay 1001357397 50.0 CFM 47.0 CFM 1.0 sones 8.1 CFM/W 3 in. diameter
HomeWerks Worldwide 7140-50 50.0 CFM 43.4 CFM 1.0 sones 3.0 CFM/W 4 in. diameter
HomeWerks Worldwide 7140-50-G3 50.0 CFM 36.1 CFM 1.0 sones 3.0 CFM/W 4 in. diameter
MaxLite EBF17-50-1-W 50.0 CFM 49.3 CFM 1.0 sones 3.7 CFM/W 3 in. diameter
RAB CEP8S 50.0 CFM 48.8 CFM 1.0 sones 5.1 CFM/W 3 in. diameter
Revent RVS50 50.0 CFM 50.0 CFM 1.0 sones 9.1 CFM/W 4 in. diameter
Revent RVSH50 50.0 CFM 50.0 CFM 1.0 sones 9.1 CFM/W 4 in. diameter
Tech Drive FA-BF-01-L 50.0 CFM 45.1 CFM 1.0 sones 3.8 CFM/W 3 in. diameter
Tech Drive TD-BF-13 50.0 CFM 47.0 CFM 1.0 sones 8.1 CFM/W 3 in. diameter
VENTECHLATION BPT12-13E 50.0 CFM 47.0 CFM 1.0 sones 8.1 CFM/W 3 in. diameter
VOTATEC VO-FN4W18-AC-50 50.0 CFM 43.4 CFM 1.0 sones 3.0 CFM/W 4 in. diameter
Ortech ODC-1109 116.0 CFM 106.8 CFM 1.1 sones 4.7 CFM/W 4 in. diameter
AERO PURE ABF110G16W 110.0 CFM 83.6 CFM 1.1 sones 4.4 CFM/W 4 in. diameter
Air King AK110LS6 110.0 CFM 103.3 CFM 1.1 sones 3.9 CFM/W 6 in. diameter
Aria QBV01100 110.0 CFM 101.5 CFM 1.1 sones 4.5 CFM/W 4 in. diameter
AUPU AV11A3 110.0 CFM 83.6 CFM 1.1 sones 4.4 CFM/W 4 in. diameter
Good Housekeeping 84006 110.0 CFM 101.5 CFM 1.1 sones 4.5 CFM/W 4 in. diameter
Miseno MBF110AWH 110.0 CFM 83.6 CFM 1.1 sones 4.4 CFM/W 4 in. diameter
Panasonic Eco Solutions RG-N110LHA 110.0 CFM 111.2 CFM 1.1 sones 9.5 CFM/W 4 in. diameter
Panasonic RG-S100A 100.0 CFM 100.1 CFM 1.1 sones 7.6 CFM/W 4 in. diameter
Broan (Canada) EZ80C 80.0 CFM 65.6 CFM 1.1 sones 3.7 CFM/W 4 in. diameter
Commercial Electric 7132-12-CE 80.0 CFM 57.1 CFM 1.1 sones 3.3 CFM/W 4 in. diameter
Fantech SMPL80 (484300) 80.0 CFM 75.0 CFM 1.1 sones 5.0 CFM/W 4 in. diameter
Fantech SMPL80L (484301) 80.0 CFM 75.0 CFM 1.1 sones 5.0 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-01-BN 80.0 CFM 65.4 CFM 1.1 sones 4.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7117-01-WH 80.0 CFM 65.4 CFM 1.1 sones 4.6 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80 80.0 CFM 62.9 CFM 1.1 sones 4.1 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80-G4 80.0 CFM 61.2 CFM 1.1 sones 3.7 CFM/W 4 in. diameter
Utilitech 7105-08-L 80.0 CFM 59.9 CFM 1.1 sones 3.5 CFM/W 4 in. diameter
Broan EZ80 70.0 CFM 60.5 CFM 1.1 sones 3.4 CFM/W 3 in. diameter
Broan LP80 70.0 CFM 60.5 CFM 1.1 sones 3.4 CFM/W 3 in. diameter
Broan LP80=LP80HwithLP80F 70.0 CFM 60.5 CFM 1.1 sones 3.4 CFM/W 3 in. diameter
Revent RVL50 50.0 CFM 47.0 CFM 1.1 sones 7.6 CFM/W 4 in. diameter
Revent RVLH50 50.0 CFM 47.0 CFM 1.1 sones 7.6 CFM/W 4 in. diameter
Tech Drive TD-BF-23L-5CCT(BL) 130.0 CFM 116.4 CFM 1.2 sones 4.6 CFM/W 5 in. diameter

Who should avoid or adjust scope around ENERGY STAR Bathroom Exhaust Fans — Models 346–460?

Choosing ENERGY STAR Bathroom Exhaust Fans — Models 346–460 depends directly on home age, plumbing drain access, soil clay behavior, and licensing scope; no single remodeling approach fits every household budget or structural condition.

Limitations & Who Should Skip

  • Skip DIY fixture or slab shortcuts if pre-1978 lead paint (>6 sq ft) under EPA 40 CFR 745 or structural wall bowing >=2 in applies.
  • Original Medicare Parts A and B reimburse $0 toward residential bathroom construction under federal Medicare rules; confirm grants beforehand.
  • Commercial contractor quotes multiply raw BLS base wages by overhead, licensing bond, workers' comp, and permit fees.

Best-Fit Homeowner Profiles

  • Best for bid verification: Homeowners comparing ENERGY STAR Bathroom Exhaust Fans — Models 346–460 against 2025 BLS trade hourly rates and official state licensing portals before signing contracts.
  • Who should choose permitted upgrades: Owners planning zero-threshold curbless ADA conversions or permanent IRC R702.4.2 tile systems.
  • Ideal for slope & drainage audits: Property owners cross-checking EPA WaterSense specs and USDA clay data to reject inflated whole-house sales pitches.

What key rules and numbers govern ENERGY STAR Bathroom Exhaust Fans — Models 346–460?

Questions below summarize primary US agency datasets, statutory limits, and IRC, IPC, or NEC compliance rules affecting ENERGY STAR Bathroom Exhaust Fans — Models 346–460.

Do bathrooms need an exhaust fan?

Yes. Residential building codes (IRC M1505 / ASHRAE 62.2) require every bathroom containing a bathtub or shower to provide mechanical exhaust ventilation delivering at least 50 CFM intermittent or 20 CFM continuous airflow vented directly to the exterior—never terminating into an attic soffit or unvented chase.

How to tell if a bathroom exhaust fan is working properly?

Test draw with a single square of toilet tissue held under the grille; if suction cannot hold the paper or mirror condensation lingers more than 15 minutes, measure attic duct diameter. Corrugated 3-inch flex ducts commonly choke 0.1 in. w.g. blower output by 35% to 55% compared with 4-inch smooth rigid metal ducts.

Do I need an electrician to install an extractor fan in my bathroom?

When swapping an existing ceiling fan housing onto a working wall switch, basic mechanical replacement is often straightforward, whereas running a new dedicated circuit, wiring GFCI branch protection under IRC E3902.1, or adding a fan-heater load exceeding 15 amps requires a licensed electrician and municipal electrical permit.

What to avoid when renovating a bathroom?

Avoid installing paper-faced drywall behind wet shower tile (violates IRC R702.4.2), venting exhaust fans into unvented attics or 3-inch kinked flex duct, skipping pre-1978 EPA Lead RRP containment above 6 sq ft, and signing unverified bids before checking official state contractor licensing portals.

What official benchmarks establish ENERGY STAR Bathroom Exhaust Fans , Models 346-460 thresholds here?

GradeMark anchors ENERGY STAR Bathroom Exhaust Fans , Models 346-460 on primary agency metrics including Models Shown (115) and Total Catalog (1,145). This catalog slice lists 115 ENERGY STAR certified bathroom exhaust fans (Models 346-460 out of 1,145 nationwide) with tested airflow. All inputs come from verifiable US government records or OEM spec sheets.

How does Models Shown interact with local IRC, IPC, and NEC residential codes?

For ENERGY STAR Bathroom Exhaust Fans , Models 346-460, federal statutory metrics like Models Shown (115) and Median Efficacy (4.7 CFM/W) operate alongside city-adopted residential IRC, IPC plumbing, and NEC 210.8 / 680.71 electrical inspection schedules rather than commercial 2010 ADA rules.

Which contractor bid checks apply when budgeting ENERGY STAR Bathroom Exhaust Fans , Models 346-460?

Separate Models Shown (115) and Total Catalog (1,145) cleanly inside itemized estimates for ENERGY STAR Bathroom Exhaust Fans , Models 346-460, checking 2021-2026 BLS material Producer Price Index shifts (+33% to +47%) and May 2025 BLS hourly wage baselines.

Who should pause or request an independent PE or permit audit on ENERGY STAR Bathroom Exhaust Fans , Models 346-460?

Pause before paying >30% upfront deposits on ENERGY STAR Bathroom Exhaust Fans , Models 346-460 when contractors refuse written SKU sheets, claim Original Medicare pays ($0 under federal Medicare rules), or omit pre-1978 EPA Lead RRP containment (>6 sq ft).

Can homeowners combine VA SAH/HISA, USDA 504, or IRS Pub 502 with ENERGY STAR Bathroom Exhaust Fans , Models 346-460?

Yes, when pre-approved prior to construction: qualified veterans use VA SAH ($133,042 FY27) or HISA ($6,800/$2,000), age-62+ rural owners check USDA 504 ($10,000), and taxpayers apply IRS Pub 502 medical deductions above 7.5% AGI.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)
  3. Occupational Employment and Wage Statistics (OEWS) State Estimates — SOC 47-1011, 47-2031, 47-2044, 47-2051, 47-2152 — U.S. Bureau of Labor Statistics, May 2025 OEWS State Release (retrieved 2026-11-23)
  4. Producer Price Index (PPI) — Construction Materials & Concrete Series — U.S. Bureau of Labor Statistics, 2021-2026 Monthly PPI Flat Files (retrieved 2026-11-23)
  5. VA Disability Housing Grants (SAH, SHA, HISA) FY 2027 Statutory Limits — U.S. Department of Veterans Affairs, FY 2027 (retrieved 2026-11-23)
  6. 38 CFR Part 17 §§ 17.3100-17.3130 — Home Improvements and Structural Alterations (HISA) — eCFR / Office of the Federal Register, 2026-01-01 (retrieved 2026-11-23)
  7. Direct Single Family Housing Loans and Grants Programs (87 FR 6772 — Section 504) — USDA Rural Housing Service / Federal Register, 87 FR 6772 (retrieved 2026-11-23)
  8. IRS Publication 502: Medical and Dental Expenses (Capital Expenses) — Internal Revenue Service, 2025/2026 (retrieved 2026-11-23)
  9. International Residential Code (IRC R308.4.5, M1505) & International Plumbing Code (IPC 412.3 / ASSE 1016) — International Code Council (Numerical Thresholds Cited Only), 2021/2024 Editions (retrieved 2026-11-23)
  10. 2010 ADA Standards for Accessible Design (28 CFR Part 36, Chapter 6) — U.S. Department of Justice, 2010 Standards (retrieved 2026-11-23)
  11. 40 CFR Part 745 Subpart E — Lead-Based Paint Renovation, Repair, and Painting (RRP) — U.S. EPA / eCFR, 2026-01-01 (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories