Skip to main content
Grant Estimator

ENERGY STAR Bathroom Exhaust Fans — Models 806–920

Catalog section (Models 806–920 of 1,145 total certified blowers) from U.S. EPA ENERGY STAR dataset 8dv7-nngq.
Direct Reference Summary

This catalog slice lists 115 ENERGY STAR certified bathroom exhaust fans (Models 806-920 out of 1,145 nationwide) with tested airflow at 0.1 in. and 0.25 in. w.g., acoustic sones (fleet median 1.0 sones), and motor efficacy (median 4.7 CFM/W). Compare verified EPA WaterSense and ENERGY STAR certified assemblies filtered from active public registries for ENERGY STAR Bathroom Exhaust Fans — Models 806–920 before ordering valves or trim.

Models Shown
115
Total Catalog
1,145
Median Efficacy
4.7 CFM/W
Median CFM
110 CFM
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

How have U.S. plumbing and remodeling material costs shifted from 2021 to 2026?

BLS Producer Price Index trajectories climbed steeply from 349.2 in 2021 to 452.8 through late 2026, setting clear baseline separation between labor pay and supply inflation.

BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Bar trend chart for BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026) across 6 periods (2021 to 2026). First: 349.1; latest: 452.8.BLS PPI: Vitreous China Plumbing Fixtures Annual Average (WPU1054, 2021-2026)Unit: idx0.0226.4452.82021: 349.1349.120212022: 385.5385.520222023: 395.0395.020232024: 401.4401.420242025: 424.1424.120252026: 452.8452.82026

How does exhaust duct geometry change static pressure?

Smooth 4-in or 6-in rigid steel ducts terminated outdoors preserve ~82% of rated fan CFM at 0.25 in. w.g., while sagging 3-in attic flex ducts choke airflow below code minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which ENERGY STAR Bathroom Exhaust Fans — Models 806–920 records match your engineering filters?

Filter verified government registry entries by threshold category or type a brand, model SKU, or state keyword below to narrow matching records instantaneously.

ENERGY STAR fan Models 806–920 — filter by acoustic tier or search by brand
Broan QTXE110150DC=QTXEDCH with QTXE110150DCF 150.0 CFM 147.8 CFM Unpublished 11.0 CFM/W 6 in. diameter
Broan QTXE110150DCL 150.0 CFM 147.8 CFM Unpublished 11.0 CFM/W 6 in. diameter
Broan QTXE110150DCL=QTXEDCLH with QTXE110150DCLF 150.0 CFM 147.8 CFM Unpublished 11.0 CFM/W 6 in. diameter
Delta SMT150D 150.0 CFM 150.5 CFM Unpublished 8.9 CFM/W 6 in. diameter
Fantech S110-130-150 (484315) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech S110-130-150L (484316) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150H (484317) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150LH (484318) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
Fantech SC110-130-150LHO (484319) 150.0 CFM 150.0 CFM Unpublished 12.9 CFM/W 6 in. diameter
KOHLER 34454 150.0 CFM 126.0 CFM Unpublished 4.4 CFM/W 6 in. diameter
KOHLER 34454-NA 150.0 CFM 126.0 CFM Unpublished 4.4 CFM/W 6 in. diameter
KOHLER 34455 150.0 CFM 125.1 CFM Unpublished 4.5 CFM/W 6 in. diameter
KOHLER 34455-NA 150.0 CFM 125.1 CFM Unpublished 4.5 CFM/W 6 in. diameter
KOHLER 34456 150.0 CFM 126.0 CFM Unpublished 4.4 CFM/W 6 in. diameter
KOHLER 34456-NA 150.0 CFM 126.0 CFM Unpublished 4.4 CFM/W 6 in. diameter
KOHLER 34457 150.0 CFM 125.1 CFM Unpublished 4.5 CFM/W 6 in. diameter
KOHLER 34457-NA 150.0 CFM 125.1 CFM Unpublished 4.5 CFM/W 6 in. diameter
KOHLER K-34454 150.0 CFM 126.0 CFM Unpublished 4.4 CFM/W 6 in. diameter
KOHLER K-34454-NA 150.0 CFM 126.0 CFM Unpublished 4.4 CFM/W 6 in. diameter
KOHLER K-34455 150.0 CFM 125.1 CFM Unpublished 4.5 CFM/W 6 in. diameter
KOHLER K-34455-NA 150.0 CFM 125.1 CFM Unpublished 4.5 CFM/W 6 in. diameter
KOHLER K-34456 150.0 CFM 126.0 CFM Unpublished 4.4 CFM/W 6 in. diameter
KOHLER K-34456-NA 150.0 CFM 126.0 CFM Unpublished 4.4 CFM/W 6 in. diameter
KOHLER K-34457 150.0 CFM 125.1 CFM Unpublished 4.5 CFM/W 6 in. diameter
KOHLER K-34457-NA 150.0 CFM 125.1 CFM Unpublished 4.5 CFM/W 6 in. diameter
Panasonic Eco Solutions FV-1315RQ1 150.0 CFM 122.4 CFM Unpublished 5.5 CFM/W 6 in. diameter
Panasonic FV-1115VK3 150.0 CFM 158.7 CFM Unpublished 13.7 CFM/W 6 in. diameter
Panasonic FV-1115VK3 with FV-VS15VK1 150.0 CFM 158.7 CFM Unpublished 13.7 CFM/W 6 in. diameter
Panasonic FV-1115VKL3 150.0 CFM 152.1 CFM Unpublished 12.2 CFM/W 6 in. diameter
Panasonic FV-1115VKL3 with FV-VS15VK1 150.0 CFM 152.1 CFM Unpublished 12.2 CFM/W 6 in. diameter
Panasonic FV-1115VQ1 150.0 CFM 154.7 CFM Unpublished 12.9 CFM/W 6 in. diameter
Panasonic FV-1115VQL1 150.0 CFM 146.2 CFM Unpublished 11.7 CFM/W 6 in. diameter
Panasonic FV-1315RQ2 150.0 CFM 143.3 CFM Unpublished 10.6 CFM/W 6 in. diameter
Panasonic RG-C1315A 150.0 CFM 143.3 CFM Unpublished 10.6 CFM/W 6 in. diameter
Panasonic RG-C1315LA 150.0 CFM 143.3 CFM Unpublished 10.6 CFM/W 6 in. diameter
S&P PCD150 150.0 CFM 159.6 CFM Unpublished 10.6 CFM/W 6 in. diameter
S&P TD-125XS 150.0 CFM N/A CFM Unpublished 4.6 CFM/W 5 in. diameter
Elica EAL330ES 141.1 CFM 214.5 CFM Unpublished 3.8 CFM/W 3.25 x 10.01 in. rectangular
ACIQ AEPD140-3 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
Broan L100E 140.0 CFM 100.4 CFM Unpublished 5.5 CFM/W 8 in. diameter
CFM TF140-EC 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
Haier QVE110DTWW 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
Ortech ODD-110-18PB 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
S&P PCD110XP 140.0 CFM 146.6 CFM Unpublished 11.5 CFM/W 6 in. diameter
GE JVX5305DJBB 139.0 CFM N/A CFM Unpublished 3.4 CFM/W 3.25 x 10 in. rectangular
Field Controls FAPV-L 138.1 CFM 106.0 CFM Unpublished 5.0 CFM/W 6 in. diameter
Whirlpool Corporation WVW73UC0LS 132.2 CFM N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Air King F130D 130.0 CFM N/A CFM Unpublished 5.4 CFM/W 6 in. diameter
Air King QFAMD 130.0 CFM N/A CFM Unpublished 5.4 CFM/W 6 in. diameter
AUPU V6-13H 130.0 CFM 135.8 CFM Unpublished 8.9 CFM/W 4 in. diameter
AUPU V6-13HL 130.0 CFM 138.7 CFM Unpublished 8.1 CFM/W 4 in. diameter
AUPU V6-13HML 130.0 CFM 138.7 CFM Unpublished 8.1 CFM/W 4 in. diameter
AUPU V6-13HS 130.0 CFM 135.8 CFM Unpublished 8.9 CFM/W 4 in. diameter
Broan AMG03RSS 130.0 CFM N/A CFM Unpublished 4.2 CFM/W 3.25 x 10 in. rectangular
Broan AMG03RWW 130.0 CFM N/A CFM Unpublished 4.2 CFM/W 3.25 x 10 in. rectangular
Broan AMM03RSS 130.0 CFM N/A CFM Unpublished 4.2 CFM/W 3.25 x 10 in. rectangular
Broan PM400SS 130.0 CFM N/A CFM Unpublished 3.6 CFM/W 3.25 x 10 in. rectangular
Delta SMT130H 130.0 CFM 126.3 CFM Unpublished 11.4 CFM/W 6 in. diameter
Delta SMT130M 130.0 CFM 126.3 CFM Unpublished 11.4 CFM/W 6 in. diameter
KOHLER 34454 130.0 CFM 106.0 CFM Unpublished 3.9 CFM/W 4 in. diameter
KOHLER 34454-NA 130.0 CFM 106.0 CFM Unpublished 3.9 CFM/W 4 in. diameter
KOHLER 34455 130.0 CFM 103.7 CFM Unpublished 3.7 CFM/W 4 in. diameter
KOHLER 34455-NA 130.0 CFM 103.7 CFM Unpublished 3.7 CFM/W 4 in. diameter
KOHLER 34456 130.0 CFM 106.0 CFM Unpublished 3.9 CFM/W 4 in. diameter
KOHLER 34456-NA 130.0 CFM 106.0 CFM Unpublished 3.9 CFM/W 4 in. diameter
KOHLER 34457 130.0 CFM 103.7 CFM Unpublished 3.7 CFM/W 4 in. diameter
KOHLER 34457-NA 130.0 CFM 103.7 CFM Unpublished 3.7 CFM/W 4 in. diameter
KOHLER K-34454 130.0 CFM 106.0 CFM Unpublished 3.9 CFM/W 4 in. diameter
KOHLER K-34454-NA 130.0 CFM 106.0 CFM Unpublished 3.9 CFM/W 4 in. diameter
KOHLER K-34455 130.0 CFM 103.7 CFM Unpublished 3.7 CFM/W 4 in. diameter
KOHLER K-34455-NA 130.0 CFM 103.7 CFM Unpublished 3.7 CFM/W 4 in. diameter
KOHLER K-34456 130.0 CFM 106.0 CFM Unpublished 3.9 CFM/W 4 in. diameter
KOHLER K-34456-NA 130.0 CFM 106.0 CFM Unpublished 3.9 CFM/W 4 in. diameter
KOHLER K-34457 130.0 CFM 103.7 CFM Unpublished 3.7 CFM/W 4 in. diameter
KOHLER K-34457-NA 130.0 CFM 103.7 CFM Unpublished 3.7 CFM/W 4 in. diameter
S&P RF8-120EC 130.0 CFM N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
S&P RF8-120EC-ES24V 130.0 CFM N/A CFM Unpublished 4.9 CFM/W 6 in. diameter
Whirlpool Corporation WVU7130JS 130.0 CFM N/A CFM Unpublished 3.7 CFM/W 3.25 x 10 in. rectangular
Aprilaire 8144NC 124.0 CFM N/A CFM Unpublished 5.1 CFM/W 6 in. diameter
BSH Home Appliances Corporation HCP30E51UC 122.3 CFM 256.3 CFM Unpublished 3.7 CFM/W 8 in. diameter
Air King ESQZ2308 120.0 CFM N/A CFM Unpublished 7.9 CFM/W 3.25 x 1 in. rectangular
Air King ESZ303ADA 120.0 CFM N/A CFM Unpublished 7.9 CFM/W 3.25 x 1 in. rectangular
Air King ESZ306ADA 120.0 CFM N/A CFM Unpublished 7.9 CFM/W 3.25 x 1 in. rectangular
Air King ESZ363ADA 120.0 CFM N/A CFM Unpublished 7.9 CFM/W 3.25 x 1 in. rectangular
Air King ESZ368ADA 120.0 CFM N/A CFM Unpublished 7.9 CFM/W 3.25 x 1 in. rectangular
Best HBN53696SS 120.0 CFM N/A CFM Unpublished 13.2 CFM/W 8 in. diameter
Fantech FR 100 (411330) 120.0 CFM N/A CFM Unpublished 6.3 CFM/W 4 in. diameter
Ortech OIF4-140 120.0 CFM N/A CFM Unpublished 4.4 CFM/W 4 in. diameter
Greenheck CSP-A125 113.0 CFM 103.0 CFM Unpublished 5.2 CFM/W 6 x 8 in. rectangular
AERO PURE ABF110DHL5W 110.0 CFM 93.9 CFM Unpublished 7.4 CFM/W 4 in. diameter
AERO PURE ABF110DHL6W 110.0 CFM 93.9 CFM Unpublished 7.4 CFM/W 4 in. diameter
AERO PURE ABFS0511DL6W 110.0 CFM 111.2 CFM Unpublished 7.8 CFM/W 4 in. diameter
Air King E80S 110.0 CFM 115.9 CFM Unpublished 4.5 CFM/W 6 in. diameter
Air King E80SH 110.0 CFM 115.9 CFM Unpublished 4.5 CFM/W 6 in. diameter
AUPU AV0511DSL3 110.0 CFM 93.9 CFM Unpublished 7.4 CFM/W 4 in. diameter
AUPU AVS0511DL3 110.0 CFM 111.2 CFM Unpublished 7.8 CFM/W 4 in. diameter
AUPU B6-11HF 110.0 CFM 89.5 CFM Unpublished 9.7 CFM/W 4 in. diameter
AUPU B6-11HL1 110.0 CFM 87.2 CFM Unpublished 9.7 CFM/W 4 in. diameter
AUPU B6-11HR 110.0 CFM 87.2 CFM Unpublished 9.7 CFM/W 4 in. diameter
AUPU BF6-S13C 110.0 CFM 89.5 CFM Unpublished 9.7 CFM/W 4 in. diameter
AUPU BF6-S13CL 110.0 CFM 87.2 CFM Unpublished 9.7 CFM/W 4 in. diameter
Broan AE50110DC 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DC = A000HFKT with AE50110DCF 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DC = A000HFKTC WITH AE50110DCF 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DC = A000HFNF with AE50110DCF 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DCL 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AE50110DCS 110.0 CFM 112.1 CFM Unpublished 9.6 CFM/W 4 in. diameter
Broan AMG63RSS 110.0 CFM N/A CFM Unpublished 3.7 CFM/W 3.25 x 10 in. rectangular
Broan-Nutone PCPE811 110.0 CFM 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter
Broan-Nutone PCPE811K 110.0 CFM 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter
Broan-Nutone PCPE811K = PCPE811H with PCPE811KF 110.0 CFM 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter
Broan-Nutone PCPER811 110.0 CFM 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter
Broan-Nutone PCPER811 = PCPE811H with PCPER811F 110.0 CFM 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter
Broan PCPE811CCTK 110.0 CFM 94.1 CFM Unpublished 4.2 CFM/W 4 in. diameter
Broan ZB110HL1 110.0 CFM 113.2 CFM Unpublished 16.2 CFM/W 6 in. diameter

Who should avoid or adjust scope around ENERGY STAR Bathroom Exhaust Fans — Models 806–920?

Choosing ENERGY STAR Bathroom Exhaust Fans — Models 806–920 depends directly on home age, plumbing drain access, soil clay behavior, and licensing scope; no single remodeling approach fits every household budget or structural condition.

Limitations & Who Should Skip

  • Skip DIY fixture or slab shortcuts if pre-1978 lead paint (>6 sq ft) under EPA 40 CFR 745 or structural wall bowing >=2 in applies.
  • Original Medicare Parts A and B reimburse $0 toward residential bathroom construction under federal Medicare rules; confirm grants beforehand.
  • Commercial contractor quotes multiply raw BLS base wages by overhead, licensing bond, workers' comp, and permit fees.

Best-Fit Homeowner Profiles

  • Best for bid verification: Homeowners comparing ENERGY STAR Bathroom Exhaust Fans — Models 806–920 against 2025 BLS trade hourly rates and official state licensing portals before signing contracts.
  • Who should choose permitted upgrades: Owners planning zero-threshold curbless ADA conversions or permanent IRC R702.4.2 tile systems.
  • Ideal for slope & drainage audits: Property owners cross-checking EPA WaterSense specs and USDA clay data to reject inflated whole-house sales pitches.

What key rules and numbers govern ENERGY STAR Bathroom Exhaust Fans — Models 806–920?

Questions below summarize primary US agency datasets, statutory limits, and IRC, IPC, or NEC compliance rules affecting ENERGY STAR Bathroom Exhaust Fans — Models 806–920.

Do bathrooms need an exhaust fan?

Yes. Residential building codes (IRC M1505 / ASHRAE 62.2) require every bathroom containing a bathtub or shower to provide mechanical exhaust ventilation delivering at least 50 CFM intermittent or 20 CFM continuous airflow vented directly to the exterior—never terminating into an attic soffit or unvented chase.

How to tell if a bathroom exhaust fan is working properly?

Test draw with a single square of toilet tissue held under the grille; if suction cannot hold the paper or mirror condensation lingers more than 15 minutes, measure attic duct diameter. Corrugated 3-inch flex ducts commonly choke 0.1 in. w.g. blower output by 35% to 55% compared with 4-inch smooth rigid metal ducts.

Do I need an electrician to install an extractor fan in my bathroom?

When swapping an existing ceiling fan housing onto a working wall switch, basic mechanical replacement is often straightforward, whereas running a new dedicated circuit, wiring GFCI branch protection under IRC E3902.1, or adding a fan-heater load exceeding 15 amps requires a licensed electrician and municipal electrical permit.

What to avoid when renovating a bathroom?

Avoid installing paper-faced drywall behind wet shower tile (violates IRC R702.4.2), venting exhaust fans into unvented attics or 3-inch kinked flex duct, skipping pre-1978 EPA Lead RRP containment above 6 sq ft, and signing unverified bids before checking official state contractor licensing portals.

What official benchmarks establish ENERGY STAR Bathroom Exhaust Fans , Models 806-920 thresholds here?

GradeMark anchors ENERGY STAR Bathroom Exhaust Fans , Models 806-920 on primary agency metrics including Models Shown (115) and Total Catalog (1,145). This catalog slice lists 115 ENERGY STAR certified bathroom exhaust fans (Models 806-920 out of 1,145 nationwide) with tested airflow. All inputs come from verifiable US government records or OEM spec sheets.

How does Models Shown interact with local IRC, IPC, and NEC residential codes?

For ENERGY STAR Bathroom Exhaust Fans , Models 806-920, federal statutory metrics like Models Shown (115) and Median Efficacy (4.7 CFM/W) operate alongside city-adopted residential IRC, IPC plumbing, and NEC 210.8 / 680.71 electrical inspection schedules rather than commercial 2010 ADA rules.

Which contractor bid checks apply when budgeting ENERGY STAR Bathroom Exhaust Fans , Models 806-920?

Separate Models Shown (115) and Total Catalog (1,145) cleanly inside itemized estimates for ENERGY STAR Bathroom Exhaust Fans , Models 806-920, checking 2021-2026 BLS material Producer Price Index shifts (+33% to +47%) and May 2025 BLS hourly wage baselines.

Who should pause or request an independent PE or permit audit on ENERGY STAR Bathroom Exhaust Fans , Models 806-920?

Pause before paying >30% upfront deposits on ENERGY STAR Bathroom Exhaust Fans , Models 806-920 when contractors refuse written SKU sheets, claim Original Medicare pays ($0 under federal Medicare rules), or omit pre-1978 EPA Lead RRP containment (>6 sq ft).

Can homeowners combine VA SAH/HISA, USDA 504, or IRS Pub 502 with ENERGY STAR Bathroom Exhaust Fans , Models 806-920?

Yes, when pre-approved prior to construction: qualified veterans use VA SAH ($133,042 FY27) or HISA ($6,800/$2,000), age-62+ rural owners check USDA 504 ($10,000), and taxpayers apply IRS Pub 502 medical deductions above 7.5% AGI.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)
  3. Occupational Employment and Wage Statistics (OEWS) State Estimates — SOC 47-1011, 47-2031, 47-2044, 47-2051, 47-2152 — U.S. Bureau of Labor Statistics, May 2025 OEWS State Release (retrieved 2026-11-23)
  4. Producer Price Index (PPI) — Construction Materials & Concrete Series — U.S. Bureau of Labor Statistics, 2021-2026 Monthly PPI Flat Files (retrieved 2026-11-23)
  5. VA Disability Housing Grants (SAH, SHA, HISA) FY 2027 Statutory Limits — U.S. Department of Veterans Affairs, FY 2027 (retrieved 2026-11-23)
  6. 38 CFR Part 17 §§ 17.3100-17.3130 — Home Improvements and Structural Alterations (HISA) — eCFR / Office of the Federal Register, 2026-01-01 (retrieved 2026-11-23)
  7. Direct Single Family Housing Loans and Grants Programs (87 FR 6772 — Section 504) — USDA Rural Housing Service / Federal Register, 87 FR 6772 (retrieved 2026-11-23)
  8. IRS Publication 502: Medical and Dental Expenses (Capital Expenses) — Internal Revenue Service, 2025/2026 (retrieved 2026-11-23)
  9. International Residential Code (IRC R308.4.5, M1505) & International Plumbing Code (IPC 412.3 / ASSE 1016) — International Code Council (Numerical Thresholds Cited Only), 2021/2024 Editions (retrieved 2026-11-23)
  10. 2010 ADA Standards for Accessible Design (28 CFR Part 36, Chapter 6) — U.S. Department of Justice, 2010 Standards (retrieved 2026-11-23)
  11. 40 CFR Part 745 Subpart E — Lead-Based Paint Renovation, Repair, and Painting (RRP) — U.S. EPA / eCFR, 2026-01-01 (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories